Unit 47 Review

Unit 47 Review

University

35 Qs

quiz-placeholder

Similar activities

DxC 700 AU

DxC 700 AU

University

30 Qs

LO1.2_Boiler Fittings

LO1.2_Boiler Fittings

University

30 Qs

ACR-202-Unit 27 Commercial Ice Machines

ACR-202-Unit 27 Commercial Ice Machines

University

36 Qs

Unit 50 Review

Unit 50 Review

University

34 Qs

UNIT TEST HEAT AND MASS TRANSFER

UNIT TEST HEAT AND MASS TRANSFER

University

35 Qs

Unit 48 - Cooling Towers and Pumps

Unit 48 - Cooling Towers and Pumps

University

30 Qs

SSC - Revision Paper 8

SSC - Revision Paper 8

University

40 Qs

ACR101 Unit 2 Matter & Energy (CRF) - Mr. Graham

ACR101 Unit 2 Matter & Energy (CRF) - Mr. Graham

University

37 Qs

Unit 47 Review

Unit 47 Review

Assessment

Quiz

Professional Development

University

Medium

Created by

Randall Graham

Used 4+ times

FREE Resource

35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerated cabinet temperature of a high-temperature refrigeration unit ranges from ____.

25°F to 45°F

45°F to 60°F

60°F to 75°F

75°F to 95°F

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a high-temperature refrigeration unit, the boiling point of the refrigerant in the coil is normally ____ lower than the cabinet temperature.

5°F to 15°F

10°F to 20°F

25°F to 35°F

35°F to 46°F

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medium-temperature refrigerated cabinet temperatures range from ____.

5°F to 20°F

20°F to 35°F

30°F to 45°F

35°F to 50°F

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The process of ice making usually occurs in which temperature range?

0°C to 4°C

-1°C to 0°C

-2°C to 0°C

-10°C to -5°C

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the typical evaporator temperature range for low-temperature applications?

-10°F to 0°F

0°F to 5°F

5°F to 20°F

20°F to 30°F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Condensing units located outside that are required to operate year-round must have ____.

larger fan motors

CPR valves

all weather protection

head pressure control

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With the entering air to the condenser above 70°F, the temperature difference between the outdoor air and the condensing temperature on standard units will be ____.

10°F to 15°F

15°F to 20°F

20°F to 25°F

25°F to 30°F

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?

Discover more resources for Professional Development