Tightness Testing and IGEM/UP/1B

Tightness Testing and IGEM/UP/1B

Professional Development

10 Qs

quiz-placeholder

Similar activities

ISO/IEC 17025:2017 LMS Requirements (Part 2)

ISO/IEC 17025:2017 LMS Requirements (Part 2)

Professional Development

10 Qs

STAAR State Assessments Quiz

STAAR State Assessments Quiz

Professional Development

11 Qs

Categories of Invasiveness in Animal Experiments

Categories of Invasiveness in Animal Experiments

Professional Development

6 Qs

AI in Game

AI in Game

12th Grade - Professional Development

12 Qs

Colour Theory Quiz - Lesson 1

Colour Theory Quiz - Lesson 1

Professional Development

12 Qs

Science Quiz Show!

Science Quiz Show!

Professional Development

10 Qs

Glasgow Coma Scale

Glasgow Coma Scale

Professional Development

11 Qs

Bramki logiczne

Bramki logiczne

1st Grade - Professional Development

10 Qs

Tightness Testing and IGEM/UP/1B

Tightness Testing and IGEM/UP/1B

Assessment

Quiz

Science

Professional Development

Hard

Created by

Rob Anderson

Used 9+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum installation volume (IV) that can be worked on as per IGEM/UP/1B?

0.025m3

0.035m3

0.02m3

0.2m3

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum operating pressure (MOP) at the outlet of the emergency control valves (ECV) as per IGEM/UP/1B?


75mb


1bar


2bar


3bar

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum nominal bore for copper pipework as per IGEM/UP/1B?

22mm

28mm


35mm



45mm

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When conducting a let-by test the water within the U gauge raises by more than 0.25mb, what procedure would you follow?


The test would be stopped and ESP called to repair

Disconnect the ECV and spray LDF into the barrel to prove you have let-by.


Move straight onto the tightness test suspected let-by would have no detrimental affect on the test.

Connect temporary bonding across the meter than disconnect the ECV and spray LDF into the barrel to prove let-by before contacting ESP.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

      What is the maximum pressure drop allowed for an existing system with appliances fitted, a G4 meter and 35mm pipework, appliance connected and no smell of gas reported?


4mb

0mb


8mb

2.5mb

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The normal working pressure of a low pressure installation is?

19mb

20mb ± 1mb



21mb ± 2mb


23mb

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the let-by test pressure on both low and medium pressure installations?

12mb

20mb


20-21mb

7-10mb