Air Supplies

Air Supplies

Professional Development

10 Qs

quiz-placeholder

Similar activities

#D: P#ym#nt #PI V3

#D: P#ym#nt #PI V3

Professional Development

10 Qs

Introduction to SEG Funds

Introduction to SEG Funds

Professional Development

15 Qs

Code of Ethics- Madera

Code of Ethics- Madera

Professional Development

15 Qs

T&L Fun Time Quiz

T&L Fun Time Quiz

Professional Development

10 Qs

Noom day 4 | Service request 2.0

Noom day 4 | Service request 2.0

Professional Development

14 Qs

Happy Birthday Ci VIR!

Happy Birthday Ci VIR!

Professional Development

10 Qs

Quizizz Case Management

Quizizz Case Management

Professional Development

10 Qs

High Management Division

High Management Division

Professional Development

10 Qs

Air Supplies

Air Supplies

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Michael Zurek

Used 48+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of the air maintenance device is to provide a__________ air supply to the system.

regulated and filtered

regulated and restricted

warm and moist

regulated and full flow

restricted and full pressure

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of the fast fill control valve on the air maintenance device is to_______.

re-pressurize the dry system more quickly with greater airflow

allow the dry system to trip more quickly

blow out the system piping, when there is an obstruction

fill the system with water more quickly when testing

drain the system piping more quickly

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The bypass valve on the air maintenance device are_______.

normally closed when the system is in service

partially open when the system is in service, to provide a restriction in the air supply

normally open when the system is in service

only opened during fire conditions

only opened when testing the system alarms

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Nitrogen may be used in lieu of air to pressurize dry and preaction systems. One reason why nitrogen is used because_________.

it helps put out the fire more quickly

it allows the system to trip more quickly

it will plug leaks in the system piping

it helps prevent corrosion of the system piping

it prevents false tripping of the valve

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The cut-in pressure for a compressor pressure switch is defined as the pressure when ________.

the compressor starts

the valve trips

water reaches the test connection

the sprinkler fuses

the fire starts

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When installing a tank-type compressor with isolator pads _______.

torque the bolts to 90-ft lbs.

do not draw the bolts tight

install a locking compound, and torque the bolts tight.

torque the bolts to keep the pads from absorbing vibrations

draw the bolts tight to keep the compressor from moving

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When installing the compressor and isolators are used__________.

the piping must be restrained from movement with rigid type

hangers

extra heavy wall piping should be used to prevent air piping

breakage

a flexible hose should be installed between the compressor and service piping

there must be 3 feet of clear space around compressor to allow for movement

a housekeeping pad must be poured for the compressor

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?

Discover more resources for Professional Development