The video tutorial covers the process of calculating heating and cooling loads, focusing on selecting the appropriate air flow rate for AC machines. It explains the importance of choosing the maximum block lit per second to avoid oversizing and optimize design. The tutorial also provides examples of software calculations for total coil load and discusses the implications of peak load and air flow rate on system design.

Read more

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of calculating heating and cooling loads?

To select appropriate AC machines

To calculate electricity bills

To determine the size of the building

To design the building layout

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which air flow rate is recommended for selecting an AC machine?

Maximum block lit per second

Sum of peak zone lit per second

Coil lit per second

Average lit per second

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What happens when you generate a heat load report for individual spaces?

Values are doubled

Values differ significantly

Values remain the same

Values are averaged

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why should you avoid summing individual peak demands when selecting coil load?

It leads to undersizing

It is not cost-effective

It is time-consuming

It results in oversizing

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the optimized way of selecting coil load according to the software?

Selecting the maximum block lit per second

Using the average coil load

Summing individual peak demands

Selecting the minimum coil load

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How does the software determine the total coil load for a report?

By selecting the maximum value at a specific time

By averaging all values

By summing individual peak loads

By using the minimum value

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does the maximum block lit per second represent?

The total air flow rate for a year

The minimum air flow rate

The peak air flow rate at any time

The average air flow rate

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?