Advanced VFD Quiz 2

Advanced VFD Quiz 2

Professional Development

17 Qs

quiz-placeholder

Similar activities

ADAS Quiz (made by Jazz Taylor)

ADAS Quiz (made by Jazz Taylor)

12th Grade - Professional Development

15 Qs

Memorable Place/Mall

Memorable Place/Mall

Professional Development

16 Qs

SAP Outbound

SAP Outbound

Professional Development

15 Qs

Python Quiz For Starters

Python Quiz For Starters

3rd Grade - Professional Development

17 Qs

Tech Trivia R2

Tech Trivia R2

Professional Development

15 Qs

Ora 07-005

Ora 07-005

Professional Development

15 Qs

Advanced VFD Quiz 1

Advanced VFD Quiz 1

Professional Development

20 Qs

Requirement Analysis Quiz

Requirement Analysis Quiz

Professional Development

15 Qs

Advanced VFD Quiz 2

Advanced VFD Quiz 2

Assessment

Quiz

Other

Professional Development

Easy

Created by

Carlos Smith

Used 1+ times

FREE Resource

17 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the term for an object's tendency to resist changes in motion?

Momentum
Inertia
Velocity
Acceleration

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the term for the aggressiveness that the control system uses to achieve or maintain the setpoint/target position?

control feedback
setpoint adjustment
target modulation

tightness/stiffness

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which vector control mode can operate the motor either open or closed loop?

V/f

VFC

CFC

PWM

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which vector control mode only works with SEW motors?

V/f

PWM

VFC

CFC

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What kind of control system incorporates three factors that look at error from a past, present, and future perspective?

Proportional-Integral-Derivative (PID)

Feedback Control System
Reactive Control System
Static Control System

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If you do not know a system's load inertia, what should you use for this value?

3

Estimate based on personal experience.
Use the maximum load capacity of the system.

10x the motor inertia

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which stiffness value, 0.5 or 2, is more likely to cause the motor to vibrate and the VFD halt with a fault code?

2
0.5

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?