Unit 29 Test - Mr. Graham

Unit 29 Test - Mr. Graham

University

34 Qs

quiz-placeholder

Similar activities

ACR-202-Unit 26 - Applications of Refrigeration Systems

ACR-202-Unit 26 - Applications of Refrigeration Systems

University

34 Qs

USPH QUESTIONS PART 3

USPH QUESTIONS PART 3

University

31 Qs

ACR108 - Unit 14 - Automatic Controls (CRF) - Mr. Graham

ACR108 - Unit 14 - Automatic Controls (CRF) - Mr. Graham

University

34 Qs

Fundamentals of Semiconductors

Fundamentals of Semiconductors

University

30 Qs

RAC Ch. 1 VCRS Revision

RAC Ch. 1 VCRS Revision

University

30 Qs

ACR-202-Unit 25 - Special Refrigeration System Components

ACR-202-Unit 25 - Special Refrigeration System Components

University

32 Qs

ACR-106 -Unit 27 - Commercial Ice Machines

ACR-106 -Unit 27 - Commercial Ice Machines

University

36 Qs

ACR 106 - Unit 27 - Commercial Ice Machines Mr. Graham

ACR 106 - Unit 27 - Commercial Ice Machines Mr. Graham

University

37 Qs

Unit 29 Test - Mr. Graham

Unit 29 Test - Mr. Graham

Assessment

Quiz

Professional Development

University

Medium

Created by

Randall Graham

Used 8+ times

FREE Resource

34 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerated cabinet temperature of a high-temperature refrigeration unit ranges from ____.

25°F to 45°F

45°F to 60°F

60°F to 75°F

75°F to 95°F

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a high-temperature refrigeration unit, the boiling point of the refrigerant in the coil is normally ____ lower than the cabinet temperature.

5°F to 15°F

10°F to 20°F

25°F to 35°F

35°F to 46°F

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medium-temperature refrigerated cabinet temperatures range from ____.

5°F to 20°F

20°F to 35°F

30°F to 45°F

35°F to 50°F

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The process of ice making usually occurs in which temperature range?

0°C to 4°C

-10°C to -20°C

-1°C to 0°C

10°C to 20°C

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the typical evaporator temperature range for low-temperature applications?

-10°F to 0°F

0°F to 5°F

5°F to 20°F

20°F to 30°F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Troubleshooting and Typical Operating Conditions for Commercial Refrigeration Refrigeration and Air Conditioning Technology Condensing units located outside that are required to operate year-round must have ____.

larger fan motors

CPR valves

all weather protection

head pressure control

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With the entering air to the condenser above 70°F, the temperature difference between the outdoor air and the condensing temperature on standard units will be ____.

10°F to 15°F

15°F to 20°F

20°F to 25°F

25°F to 30°F