1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
The tool in figure 1 is most likely to be used for which one of the following?
Jointing copper tube.
Making fixings to masonry walls.
Making connections to plastic cisterns.
Jointing galvanised pipe.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which British Standard makes recommendation on the minimum size of cold water storage cistern for a particular property?
BS EN 12056.
b) BS 8000.
c) BS 6700.
d) BS5452.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The water flow rate from a cold water tap is 8 litres per minute, what is the flow rate measured in litres per second?
a) 0.10 l/s.
b) 0.13 l/s.
c) 0.45 l/s.
d) 0.73 l/s.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The quantity of fittings delivered to site by a plumbers merchant will be shown in a
job specification
b) site plan
c) delivery note
d) building plan.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of cold water system is normally used in a dwelling which has a high incoming water pressure?
a) Condensing.
b) Boosted.
c) Direct.
d) Indirect.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The Water Regulations require that the warning pipe in a small cold water storage cistern must be
a) at least 28 mm diameter
b) at least 22 mm diameter
c) sized to be able to cope with the flow of water should the inlet valve fail
d) fitted with a non-return valve to prevent contamination of the stored water.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the required soundness test pressure for a copper cold water supply pipe which has a maximum operating pressure of 4 bar?
a) 2 bar.
b) 4 bar.
c) 6 bar.
d) 8 bar.

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?