ACR108-Unit 41 Practice Test (CRF) - Mr. Graham

ACR108-Unit 41 Practice Test (CRF) - Mr. Graham

University

10 Qs

quiz-placeholder

Similar activities

Unit I Conduction Basics

Unit I Conduction Basics

University

10 Qs

GSM 101 B

GSM 101 B

University

10 Qs

Oxyacetylene Torch Cutting

Oxyacetylene Torch Cutting

10th Grade - University

10 Qs

Secondary 1

Secondary 1

University

10 Qs

L3 Scientific principles part 2

L3 Scientific principles part 2

University - Professional Development

15 Qs

EES 101 Week 4

EES 101 Week 4

University

10 Qs

LOTS or HOTS?

LOTS or HOTS?

University

10 Qs

Sacramento User Group

Sacramento User Group

University

10 Qs

ACR108-Unit 41 Practice Test (CRF) - Mr. Graham

ACR108-Unit 41 Practice Test (CRF) - Mr. Graham

Assessment

Quiz

Professional Development

University

Hard

Created by

Randall Graham

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When performing mechanical troubleshooting on an air-conditioning system, a technician should have _________.

gauges and temperature-testing equipment

an ohmmeter and a digital manometer

a digital manometer and a megger

an ohmmeter and megohmmeter

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The difference in temperature between the refrigerant condensing temperature and the ambient air blowing over the condenser coil is called _______.

subcooling

superheat

Delta T

temperature split

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

During standard operating conditions, there will be approximately a ____°F wet-bulb drop from the evaporator inlet to the evaporator outlet.

20

5

10

15

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The humidity in the air at the evaporator outlet will be at almost ____%.

90

50

70

80

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For a system that utilizes a R-410A compressor, the discharge line may be as hot as ____°F under normal conditions. Care must be taken when attaching a thermometer.

150

200

250

175

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Manufacturers report that a fairly high percentage of compressors returned to them under warranty are actually not defective but were reported by the technician as defective.

True

False

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A standard efficiency system usually has a refrigerant boiling temperature of about ____ °F cooler than the entering-air temperature at standard operating conditions.

35

45

15

25

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?