
FDRP2
Authored by Keith Wade
Other
2nd Grade
Used 29+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
20 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
When initially discussing the work involved in fault finding with the client, an area of consideration should be?
access arrangements
availability of parts required
total cost
materials required
2.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
A fault has been reported on an unfamiliar machine. Which information would be of most use in fault finding?
The Electrical Installation Certificate
Maintenance records
The workers using the equipment when it went wrong
The manufacturers instructions
3.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
When preparing to work on a three-phase pillar drill, the number of tests required to prove isolation has been correctly completed is?
3
9
10
12
4.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Which of the following information is not required when diagnosing a fault on a circuit that has no previous certificates in place?
The existing Electrical Installation Certificate
Events leading up to the fault
Maintenance records
The manufacturers instructions
5.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
A component has been identified as the cause of the fault but is not a stock item and requires ordering. What information should be given to the client?
The supplier’s phone number to chase delivery
The expected delivery/repair date
The part number of the item ordered
The way to bypass the faulty part, although safety will be impaired
6.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
An upgraded piece of equipment has been installed but repeatedly after 25 minutes of running, it trips out the circuit breaker. What is the most likely fault?
A short circuit
An overload
An undervoltage
A fault to earth
7.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
A customer has had new USB sockets fitted in the kitchen but can now hear a crackling noise. What is the most likely cause?
An insulation resistance fault between neutral and earth
An overvoltage outside the specification of the socket installed
A loose connection
Overloading the socket
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?