Cable and Electrical Safety Quiz

Cable and Electrical Safety Quiz

1st Grade

19 Qs

quiz-placeholder

Similar activities

Revise Days, Weeks and Months

Revise Days, Weeks and Months

1st Grade

15 Qs

Quarter 4 Interim Prep VAVA

Quarter 4 Interim Prep VAVA

1st Grade

20 Qs

HDFC Ergo NM team training module for new joiners

HDFC Ergo NM team training module for new joiners

1st - 5th Grade

20 Qs

FRACTION

FRACTION

1st Grade

16 Qs

Grade - 1 ICT

Grade - 1 ICT

1st - 2nd Grade

15 Qs

Math Diagnostic Test

Math Diagnostic Test

1st Grade

15 Qs

KUIZ FUNGSI

KUIZ FUNGSI

1st Grade

20 Qs

Math Primary 1 - Numbers 1-10

Math Primary 1 - Numbers 1-10

1st Grade

20 Qs

Cable and Electrical Safety Quiz

Cable and Electrical Safety Quiz

Assessment

Quiz

Mathematics

1st Grade

Practice Problem

Easy

Created by

Abubakar Yusuf

Used 1+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The acronym XLPE refers to a

Plain lead covered earth cable

Mineral insulated cable

Cross linked polyethylene insulated cable

Point on a cable plan where a cable is laid on top of another cable.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of gas is used in a gas filled cable?

Carbon Dioxide

Oxygen

Helium

Nitrogen

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of screening 3-phase high voltage cables is to

Stop electrolytic action

Control tangential stresses

Provide good earth continuity

Give extra mechanical protection

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On a cable plan the letters ABSD may appear. This would refer to

Aerial bundled steel distributer

Air blast system disengager

Air break switch disconnector

Aerial balanced safety distancer

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When handling cold pour resins the mandatory PPE would be

Overalls and eye protection

Disposable gloves and breathing apparatus

Breathing apparatus and overall

Eye protection and disposable gloves.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

By cable spiking what potential risk is being controlled or minimised

moisture

flashover

Results in deterioration

puncture

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The full form of PILCSWA in Underground cables refers to

Plastic insulated lead covered steel wire armoured cable

Plastic insulated laminated copper steel wire armoured cable

Paper insulated lead covered steel wire armoured cable

Paper insulated lead conductor steel wire armoured cable

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?