2 mins • 1 pt
What would be the low side elevation of a sewer drain that has a 1/16" per ft of grade and is 48.08 feet long and starts at an elevation of 96 ft?
Answer explanation
The sewer drain starts at 96 feet.
It drops a total of about 3 inches over 48.08 feet.
Converting 3 inches to feet gives us 0.25 feet.
Subtracting the drop from the starting elevation:
So, the low side elevation is approximately 95.75 feet.
The sewer drain starts at 96 feet.
It drops a total of about 3 inches over 48.08 feet.
Converting 3 inches to feet gives us 0.25 feet.
Subtracting the drop from the starting elevation:
So, the low side elevation is approximately 95.75 feet.
2.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
Where plumbing fixtures are installed on a floor with a finished floor elevation below the elevation of a manhole cover of the next upstream manhole in the public sewer, fixtures are protected by a backwater valve. Which of the following is required in a backflow valve?
Answer explanation
3.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
In a hot water tank, temperature and pressure relief valves, or a combination of thereof, and energy cutoff devices shall have a temperature setting of not more than 210 degrees F and a working pressure of how many PSI?
4.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
According to the International Plumbing Code, every dry vent shall rise vertically opto a point not less than 6 inches above the flood level rim of the highest trap with > the exception of
5.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
What is the minimum air gap for sinks, laundry trays, gooseneck back faucets n and other fixtures with an effective opening of 1-1/4 inches?
6.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
According to the International Plumbing Code, a backwater valve is used to ก prevent drainage or waste from backing up into lower fixtures. Where shall the backwater valve be installed?
7.
MULTIPLE CHOICE QUESTION
2 mins • 1 pt
Using Table 906.1 of the International Plumbing Code, what is the smallest diameter of vent if a vent that is 65 feet long is servicing a 4 inch waste stack?