Test 10 - Confocal microscopy

Test 10 - Confocal microscopy

University

10 Qs

quiz-placeholder

Similar activities

Test 8 - Polarization microscopy

Test 8 - Polarization microscopy

University

10 Qs

Science

Science

University

10 Qs

NanoTech random 1

NanoTech random 1

University

10 Qs

untitled

untitled

5th Grade - University

6 Qs

Microscope

Microscope

11th Grade - University

7 Qs

Physics Quiz 1

Physics Quiz 1

University

6 Qs

yourself

yourself

KG - University

5 Qs

NM_e2_23

NM_e2_23

University

10 Qs

Test 10 - Confocal microscopy

Test 10 - Confocal microscopy

Assessment

Quiz

Physics

University

Hard

Created by

Viktor Zakharov

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

What illumination method is used in confocal microscopy?

Köhler illumination

Critical illumination

Diffused light illumination

2.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

How to increase sensitivity when scanning in confocal mode?

Increase brightness

Reduce noise

Improve signal collection efficiency

Use an objective with a larger aperture

Increase scanning speed

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Along the Z axis, the resolution of the confocal microscope ....

is better than along the X and Y axes

is worse than along the X and Y axes

is the same as along the X and Y axes

A confocal microscope does not allow information to be obtained along this axis

4.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Select the correct statements about confocal microscopy.

At each moment in time, the signal from the entire sample is recorded

At each moment in time, the entire sample is illuminated

At any given moment in time, the signal is registered only from one point.

At any given moment in time, only one point is illuminated

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

When decreasing the pinhole diameter:

There is a decrease in confocality

The amount of transmitted scattered light is reduced

The contrast is reduced

6.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

What units and where are used in confocal microscopy?

Airy unit for describing the diameter of a pinhole

Airy unit for the distance from the objective to the specimen

Rayleigh unit for describing the thickness of an optical slice

Rayleigh unit for determining the degree of monochromaticity of radiation

Zeiss unit for the width of the radiation beam incident on the sample

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is NOT included in a confocal microscope?

Traditional light microscope

Mathematical processing algorithm

Devices allowing to realise confocal mode

Monochromator of incident radiation

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?