Phase4.mod9ECV

Phase4.mod9ECV

Professional Development

6 Qs

quiz-placeholder

Similar activities

DUBINAC-SR

DUBINAC-SR

Professional Development

6 Qs

Emergency Care

Emergency Care

Professional Development

5 Qs

Converting units km, m, cm, and mm

Converting units km, m, cm, and mm

KG - Professional Development

10 Qs

Cardiology 101

Cardiology 101

Professional Development

10 Qs

SP Somfy School

SP Somfy School

Professional Development

10 Qs

earthquake

earthquake

Professional Development

9 Qs

ACS CCN1 Quiz 1

ACS CCN1 Quiz 1

Professional Development

11 Qs

Gk Quiz 2

Gk Quiz 2

6th Grade - Professional Development

10 Qs

Phase4.mod9ECV

Phase4.mod9ECV

Assessment

Quiz

Science

Professional Development

Medium

Created by

Craig Boothright

Used 6+ times

FREE Resource

6 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

the handle on an emergency /meter control valve must always:

Fall to the off position.

Fall to the on position.

Be electrically insulated.

Have 180o Travel.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The responsibility for installation and repair to a emergency/meter control lies with:

The property owner.

The gas supplier.

The gas transporter.

The gas operative.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a supply to a property incorporates a house entry tee:

This may be used as an alternative emergency control by the gas operative.

This must not be used as an alternative emergency control by the gas operative.

This may be used as an alternative emergency control by the consumer.

This may be used as a regulating valve by the gas transporter.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a meter is fitted within an outside meter box, the emergency meter control must always be located:

Within the meter box.

Within the building.

On the outlet side of the meter.

On the outlet side of the regulator.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When remote external meter boxes are installed to supply gas to a property, in addition to all the usual controls the installation requires an intternal:

Meter regulator.

Emergency control valve.

Test point.

Meter.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When an internal meter position is identified without the inclusion of a house entry tee, then the operative must:

Inform the gas transporter.

Inform the HSE.

Not test for let by.

This installation is satisfactory.

Discover more resources for Science