CW - Mechanical Backflow Prevention Arrangements PP10

CW - Mechanical Backflow Prevention Arrangements PP10

University

10 Qs

quiz-placeholder

Similar activities

Revision Chapter 1 & 2

Revision Chapter 1 & 2

University

8 Qs

Basic Refrigeration Systems

Basic Refrigeration Systems

KG - Professional Development

10 Qs

Chapter 50 General Brakes Test Review

Chapter 50 General Brakes Test Review

University

15 Qs

Wheels, Tires, and Bearings

Wheels, Tires, and Bearings

10th Grade - University

15 Qs

Hvac - components except compressor

Hvac - components except compressor

University

10 Qs

Essential Engine Functions

Essential Engine Functions

University

10 Qs

Domestic hot water systems

Domestic hot water systems

12th Grade - Professional Development

15 Qs

PNEUMATIC TRANSPORT

PNEUMATIC TRANSPORT

University

15 Qs

CW - Mechanical Backflow Prevention Arrangements PP10

CW - Mechanical Backflow Prevention Arrangements PP10

Assessment

Quiz

Other

University

Medium

Created by

Eden Longley

Used 6+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the fluid category protection rating for a "Non-verifiable disconnector with difference between pressure zones not greater than 10%" against back-pressure?

4

3

2

X

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of heating system is mentioned in the context of using a type CA backflow preventer?

Open central heating system

Sealed central heating system

Electric heating system

Gas heating system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What type of system is shown in the diagram?

Electrical system

Gas system

Central heating system

Air conditioning system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On which devices must DB pipe interrupters not be used?

Hose union bib taps

Water heaters

Devices with a control valve restriction

Garden hoses

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How must DB pipe interrupters be fitted?

Horizontally

Vertically

At an angle

Upside down

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must not be installed downstream of DB pipe interrupters?

Control valves

Hose union bib taps

Water heaters

Valves

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To which standard does the EA single check valve conform?

BS6282 Part 2

BS6282 Part 1

BS6283 Part 1

BS6283 Part 2