Pre-test - Arumaya CMDP

Pre-test - Arumaya CMDP

Professional Development

15 Qs

quiz-placeholder

Similar activities

Ice Breaker

Ice Breaker

1st Grade - Professional Development

10 Qs

Phi Beta Sigma Fraternity, Inc. - Multiple Choice Assessment # 1

Phi Beta Sigma Fraternity, Inc. - Multiple Choice Assessment # 1

Professional Development

18 Qs

Pintuco 3 - Grupo B - Universidad Abacol

Pintuco 3 - Grupo B - Universidad Abacol

Professional Development

17 Qs

Seberapa Kenal Kamu Dengan KMI?

Seberapa Kenal Kamu Dengan KMI?

Professional Development

15 Qs

Garantia de Atendimento

Garantia de Atendimento

Professional Development

18 Qs

Quiz sur les systèmes d'un camion

Quiz sur les systèmes d'un camion

Professional Development

20 Qs

MTT RECAPITULATION

MTT RECAPITULATION

Professional Development

10 Qs

Potjera - 198.dio

Potjera - 198.dio

Professional Development

20 Qs

Pre-test - Arumaya CMDP

Pre-test - Arumaya CMDP

Assessment

Quiz

Other

Professional Development

Easy

Created by

HCBP Property

Used 1+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

1. Setiap luasan berapa meter persegi diperlukan kolom praktis (dinding internal)?
10 m2
11 m2
12 m2
13 m2

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

2. Setiap luasan berapa meter persegi diperlukan kolom praktis (dinding eksternal)?
8 m2
9 m2
10 m2
11 m2

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

3. Setiap ketinggian berapa meterkah pengecoran kolom praktis?
2 meter
2,5 meter
1 meter
1,5 meter

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

4. Setiap ketinggian berapa cm dipasang dowel/stek pada dinding bata ringan?
50 cm
55 cm
60 cm
65 cm

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

5. Berapakah % CBR untuk perkerasan jalan?

5%

6%

7%

8%

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

6. Berapakah tingkat gloss marmer (GU) yang dapat kita terima?
80 GU
90 GU
65 GU
70 GU

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

7. Berapa Psi minimum tekanan nitrogen pada pengetesan pipa refrigerant AC?
250 Psi
300 Psi
350 Psi
400 Psi

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?