t511/t711 ST Day3 Review Quiz

t511/t711 ST Day3 Review Quiz

Professional Development

10 Qs

quiz-placeholder

Similar activities

PPE -Steam Power Plant 2 SMK GIET

PPE -Steam Power Plant 2 SMK GIET

University - Professional Development

10 Qs

Testing and Lab Procedures

Testing and Lab Procedures

University - Professional Development

15 Qs

KONKERPROV 2023

KONKERPROV 2023

Professional Development

10 Qs

MTA: 98-367 Security Part 3

MTA: 98-367 Security Part 3

KG - Professional Development

15 Qs

Application training quiz

Application training quiz

Professional Development

5 Qs

Contributing to a safe work environment - HLTWHS001

Contributing to a safe work environment - HLTWHS001

Professional Development

5 Qs

Memory

Memory

Professional Development

10 Qs

GSuite Quiz

GSuite Quiz

Professional Development

10 Qs

t511/t711 ST Day3 Review Quiz

t511/t711 ST Day3 Review Quiz

Assessment

Quiz

Education

Professional Development

Hard

Created by

John Lu

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

A customer calls and complains that the newly inserted cassette is still on the cassette drawer (left side).Why?

Barcode not readable (wrong placement of cassette or BC not readable)

The cassette is expired.

Test application(E-barcode) not installed

Instrument in «Paused» state

Drawer sensor defective

2.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Initialization of the instrument stops with an error. Cdi:1090307, Error code :610.

Message:
Reagent storage, reagent cassette carrier, z-motor movement error
Message content:
Motor movement error has occurred.
Solution: For troubleshooting, see the User Assistance.
If error persists, contact Roche Service representative.

What are possible causes?

Faulty z-motor

PCB’s cables

Unteached reagent storage

defective z-brake

PCB defective

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

After replacing the reagent storage, which have to be done?

Teach reagent storage

Teach transfer unit, single module -reagent storage

Format the PCB Resource Handing2

Reset the reagent storage temperature

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Which adjustments have to be done before teaching the reagent storage?

Adjust the barcode reader

Adjust the cassette handler Y

Adjust the Cassette shaker

None

5.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which statement is correct about the RVC(reagent volume check)?

use reagent probe to do the RVC

use sample probe to do the RVC

use the cuvette to do the RVC

use photometer to do the RVC

6.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

What’s the post work after replace the Resource Handling Control BC2?

Teaching reagent storage

Teaching the transfer unit

Teaching the sampling unit

None

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

When does the drain selector switch to the condensation drain(left side)?

t711 in standby status

t711 in error status(sometimes)

t711 in offline status

t711 in D&S mode