Plumbing ripka ch7 213,214

Plumbing ripka ch7 213,214

12th Grade

10 Qs

quiz-placeholder

Similar activities

CONSTRUCTION DRAWINGS

CONSTRUCTION DRAWINGS

12th Grade

11 Qs

JENIS-JENIS SANITER

JENIS-JENIS SANITER

12th Grade

15 Qs

ESTIMASI BIAYA KONSTRUKSI

ESTIMASI BIAYA KONSTRUKSI

7th Grade - University

10 Qs

Quiz on Building Services and Plumbing Systems

Quiz on Building Services and Plumbing Systems

12th Grade

15 Qs

PAGE 152

PAGE 152

12th Grade

5 Qs

Plumbing ripka ch7 213,214

Plumbing ripka ch7 213,214

Assessment

Quiz

Architecture

12th Grade

Medium

Created by

Christopher Richard

Used 4+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of vent piping in a sanitary drainage system?

To size the piping systems for the entire job

To ensure proper installation within the local plumbing code

To convey rainwater to the storm sewer

To provide circulation of air and protect trap seals

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What do waste pipes convey in a building?

Liquid waste that is free from fecal matter

Solid or semisolid materials

Waterborne waste into the building drain

Fecal matter from water closets

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the measure of the probable discharge of wastewater and waterborne waste into a drainage system?

Stormwater drainage piping

Drainage fixture unit (dfu)

Sanitary drainage piping size

Vent piping circulation

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the basis of the drainage fixture unit system?

1 drainage fixture unit (dfu) = 10 gal. per min (gpm)

1 drainage fixture unit (dfu) = 1 cu ft of water

1 drainage fixture unit (dfu) = 7½ gal. per min (gpm)

1 drainage fixture unit (dfu) = 72 gal. per min (gpm)

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum fixture trap and drain size based on?

The ability to design and install sanitary drainage systems

The locations of the water supply and stormwater piping

The number and type of plumbing fixtures and appliances

The smallest size pipe into which the fixture may drain

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the wastewater discharge rate of a lavatory in the drainage fixture unit system?

15 gal. of water per minute

5 gal. of water per minute

10 gal. of water per minute

7½ gal. of water per minute

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What angle makes a pipe a horizontal pipe in plumbing systems?

45° from the horizontal plane

Less than 45° from the horizontal plane

Less than 45° from the vertical plane

45° from the vertical plane

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?