EPA 608 - TYPE 3

EPA 608 - TYPE 3

9th - 12th Grade

52 Qs

quiz-placeholder

Similar activities

A&P Cardiovascular System Wk 4 & 5 Test Review

A&P Cardiovascular System Wk 4 & 5 Test Review

11th Grade - University

50 Qs

Earth and Environmental Science Review

Earth and Environmental Science Review

9th Grade

50 Qs

soal Remidi AC Mobil

soal Remidi AC Mobil

11th Grade

55 Qs

Review NCD/CPR

Review NCD/CPR

8th - 12th Grade

53 Qs

HVAC 1 FALL 2024  FINALS

HVAC 1 FALL 2024 FINALS

12th Grade

49 Qs

Take Flight Book 1 & 2

Take Flight Book 1 & 2

6th Grade - University

50 Qs

Electrical Current and Circuit Quiz

Electrical Current and Circuit Quiz

12th Grade

50 Qs

Quiz Sistem AC

Quiz Sistem AC

11th Grade

50 Qs

EPA 608 - TYPE 3

EPA 608 - TYPE 3

Assessment

Quiz

Other

9th - 12th Grade

Medium

Created by

CHRISTOPHER SUGG

Used 98+ times

FREE Resource

52 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of appliance can a technician work on with a Type III Certification?

Convenience store refrigerators

Ice machines that fit under the counter

Low pressure appliances such as chillers

High pressure appliances such as heat pumps

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Low pressure appliances operate...

As a high pressure system.

In a vacuum or below atmospheric pressure.

Above atmospheric pressure.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where does the purge unit take its suction from?

The lowest point of the system

The top of the condenser

The evaporator charging valve

The bottom of the condenser

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the pressure relief device on a low-pressure chiller called?

A vent pipe

A purge unit

An evaporator valve

A rupture disc

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the boiling point of R-123 refrigerant at atmospheric pressure?

0 degrees F

83 degrees F

- 15 degrees F

26 degrees F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When charging a low pressure water chiller with R-123, charging begins with vapor, until what pressure is reached in the system?

25 "hg

18.9 "hg

0 "hg

84 psig

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the condensing temperature of a low pressure chiller is 100 degrees F, that means the high side pressure is:

19 psig

6.1 "hg

83 psig

6.1 psig

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?