Philippine Electrical Code (Subject 7) - Nth

Philippine Electrical Code (Subject 7) - Nth

University

50 Qs

quiz-placeholder

Similar activities

MatSci Prelims

MatSci Prelims

University

50 Qs

Tes Wawasan Kebangsaan LPDP 2021

Tes Wawasan Kebangsaan LPDP 2021

University

50 Qs

9º ANO - QUIZIZZ EEBA

9º ANO - QUIZIZZ EEBA

8th Grade - University

50 Qs

Ilmu Asas Technical Analysis Saham

Ilmu Asas Technical Analysis Saham

University

50 Qs

TUTORIAL GAIT

TUTORIAL GAIT

University

45 Qs

Ujian Penilaian Pengetahuan EE-320-2 (1)

Ujian Penilaian Pengetahuan EE-320-2 (1)

University

50 Qs

Sustainable Development

Sustainable Development

University

50 Qs

RoT and MX-Am War

RoT and MX-Am War

7th Grade - University

45 Qs

Philippine Electrical Code (Subject 7) - Nth

Philippine Electrical Code (Subject 7) - Nth

Assessment

Quiz

Other

University

Practice Problem

Medium

Created by

Norlan Hiponia

Used 17+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

1. What is the maximum weight, in pounds, of a lighting fixture when supported only by the screw shell of the lampholder?

2 pounds

4 pounds

6 pounds

8 pounds

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

2. What are the maximum dimensions of a lighting fixture that may be supported only by the screw shell of the lampholder?

12 inches

16 inches

18 inches

20 inches

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

3. Flexible cords shall be so connected to devices and to fittings that _____ will not be transmitted to joints or terminals.

Tension

Shock

Heat

Voltage

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

4. What is the maximum weight of a lighting fixture that is supported only by an outlet box?

6 pounds

10 pounds

25 pounds

50 pounds

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

5. To what portion of a lampholder must the grounded conductor be connected?The base

The base

The screw shell

The outlet box

The pull chain

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

6. What is the smallest size fixture wire allowed?

No. 14 AWG

No. 16 AWG

No. 18 AWG

No. 20 AWG

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

7. What is the minimum wire size allowed for pendant conductors supplying mogul-base or medium-base screw-shell lampholders?

No. 12 AWG

No. 14 AWG

No. 16 AWG

No. 18 AWG

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?