HVAC 50 QUESTION ESCO TEST

HVAC 50 QUESTION ESCO TEST

University

49 Qs

quiz-placeholder

Similar activities

Electircal Systems

Electircal Systems

12th Grade - University

52 Qs

A&P Cardiovascular System Wk 4 & 5 Test Review

A&P Cardiovascular System Wk 4 & 5 Test Review

11th Grade - University

50 Qs

Record Management

Record Management

University

50 Qs

AP Comparative Politics Final Term Quiz

AP Comparative Politics Final Term Quiz

12th Grade - University

50 Qs

BL M-02 FIRE CODE FLASHCARDS 01

BL M-02 FIRE CODE FLASHCARDS 01

University - Professional Development

50 Qs

AELE Quiz - June 8 - 10, 2021

AELE Quiz - June 8 - 10, 2021

University

50 Qs

EST 40

EST 40

University

50 Qs

Unit 03 - MEC 302

Unit 03 - MEC 302

University

46 Qs

HVAC 50 QUESTION ESCO TEST

HVAC 50 QUESTION ESCO TEST

Assessment

Quiz

Other

University

Easy

Created by

MedicKermit MedicKermit

Used 143+ times

FREE Resource

49 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To determine weather a unit has an airflow and/or refrigerant flow problem, what should the tech look for?

Air temp split of the evap coil and determine if it is higher or lower than it should be.

Air temp split of the condenser coil and determine if it is higher or lower than it should be.

Frozen Coil

Check the pressure of the coils

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The tech must obtain the _ entering and leaving the coil to determine the required temp difference across the evap coil.

wet-bulb temps of the air

pressures

dry-bulb temps of the air

AMPS

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The correct sequential order steps in the vapor compression process is:

Compression, Condensation, Expansion, Evaporation

Evaporation, Expansion, Compression, Condensation

Expansion, Compression, Evaporation, Condensation

Condensation, Expansion, Compression, Evaporation

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the temp reading across the coil is greater than the required reading for the system, what is the problem?

Refrigeration Problem

Airflow Isusse

Electrical Issue

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Airflow problems are caused by?

Dirty Evap

Restriction in Duct

Dirty Filters

All of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If there is a low temp drop across the Evap coil the problem is?

Airflow Problem

Refrigerant Flow Problem

Electrical Problem

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Air-cooled type condensers are always larger than the _ .

Compressor

Evap

Condenser

Metering Device

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?