HVAC FC 02

HVAC FC 02

Professional Development

70 Qs

quiz-placeholder

Similar activities

Krissquiz: Star Wars

Krissquiz: Star Wars

Professional Development

68 Qs

BU - MECH- ELEVATOR FLASHCARDS

BU - MECH- ELEVATOR FLASHCARDS

Professional Development

70 Qs

Soal Test HD Perawat

Soal Test HD Perawat

Professional Development

70 Qs

ADX 201 Random 3

ADX 201 Random 3

Professional Development

65 Qs

HVAC FC 07

HVAC FC 07

Professional Development

70 Qs

HOA M-02 F-01 EARLY CHRISTIAN ARCHITECTURE

HOA M-02 F-01 EARLY CHRISTIAN ARCHITECTURE

Professional Development

70 Qs

REVISION

REVISION

Professional Development

70 Qs

Marriage (Art.1-54 FC)

Marriage (Art.1-54 FC)

Professional Development

72 Qs

HVAC FC 02

HVAC FC 02

Assessment

Quiz

Other

Professional Development

Hard

Created by

Johnny Thulin

Used 2+ times

FREE Resource

70 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When may a replacement listed forced air furnace be installed in an existing closet which is less than 12 inches wider than the furnace and with a minimum clear working space not less than 3 inches along sides, back and top of the furnace?
when approved by the authority having jurisdiction
when such width is in compliance with the manufacturer"s specifications
when approved by the owner
when the installing contractor assumes full responsibility

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Piping shall be supported at distances not exceeding the spacing specified in the International Mechanical Code. The maximum interval spacing requirement for a 3/4-inch copper-alloy tubing condensate drain line, installed horizontally shall be:
20 feet
15 feet
10 feet
6 feet

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Some old large oil-filled capacitors (found in fluorescent lamp ballasts, and other applications) can leak and create a safety hazard. This dielectric fluid contains what type of material?
Class C
Carbon Dioxide
Carbon Monoxide
PCBs

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A typical psychrometric chart graphs relative humidity in percent, dry bulb and wet bulb temperatures. The dry bulb temperatures shown at the bottom of the chart range from ___.
0 degrees F to 100 degrees F
10 degrees F to 103 degrees F
20 degrees F to 107 degrees F
30 degrees F to 170 degrees F

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Constants for heat loads are defined in the text Modern Refrigeration and Air Conditioning for a 4 inch thick concrete slab with no finish as
U=0.45; R=1.34
U=0.55; R=1.44
U=0.65; R=1.54
U=0.75; R=1.64

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum wall thickness for a 1 1/2 inch nominal carbon steel pipe with threaded couplings used to transport liquid Group A1 refrigerant?
Schedule 20
Schedule 40
Schedule 80
Schedule 120

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A confined space in which a natural gas appliance has a clearance of 1 inch on the sides and back, and 6 inches on the front requires to have a MINIMUM of ____ permanent ventilation openings communicating with outside air.
two
four
one
three

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?