ACR 202 Midterm Exam.

ACR 202 Midterm Exam.

University

40 Qs

quiz-placeholder

Similar activities

CMA 310 - Anatomy of Buildings Chapters 1-3

CMA 310 - Anatomy of Buildings Chapters 1-3

University

45 Qs

Men's Haircutting

Men's Haircutting

University

35 Qs

Engines 1 Practice Finals

Engines 1 Practice Finals

University

42 Qs

Basic Hidrolik-E-Learning

Basic Hidrolik-E-Learning

11th Grade - University

37 Qs

UAS Mesin Pendingin SM III

UAS Mesin Pendingin SM III

University

40 Qs

hvac finals exam-denz

hvac finals exam-denz

University

35 Qs

CPD222 Final 2/65

CPD222 Final 2/65

University

40 Qs

ACR 202 Midterm Exam.

ACR 202 Midterm Exam.

Assessment

Quiz

Instructional Technology

University

Easy

Created by

Ulric Rodney

Used 32+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a major component of the Refrigeration cycle?

compressor

condenser

evaporator

suction-line drier

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To throttle or regulate the flow of fluid as opposed to just starting or stopping it is called .............

pulsing

modulating

rationing

mixing

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of the crankcase pressure regulating-valve is to

maintain constant pressure in the crankcase.

maintain constant pressure in the evaporator.

prevent a compressor from going into a vacuum.

prevent a compressor overload condition.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The ........... valve can move in very small increments to either open or close the suction line in response to the discharge air temperature of a refrigerated case.

electronic evaporator pressure regulator

thermostatic expansion

electronic expansion

crankcase pressure regulator

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An automatic pump down system may be used to

maintain a constant evaporator pressure during low load conditions.

raise the head pressure during low ambient conditions.

prevents surges of liquid refrigerant from entering the compressor during start up.

prevents liquid refrigerant from being trapped in the receiver.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On a one-time or non-short-cycle pump down system

a leaking solenoid valve or discharge valve will cause the system to turn back on.

only the thermostat calling again for cooling will take the system out of pump down.

the refrigerant is stored in the receiver and must be manually released back into the system.

once the system has been pumped down, it will lock out, requiring service.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Two types of relief valves are ...............

check and spring-loaded

manual and ball

spring-loaded and one-time

one-time and multiuse