Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

University

50 Qs

quiz-placeholder

Similar activities

H.O.M electric 3

H.O.M electric 3

University

51 Qs

FAA General Practice

FAA General Practice

University

45 Qs

DSL-206 Electrical 2 Final Exam

DSL-206 Electrical 2 Final Exam

University

50 Qs

Philippine Electrical Code (Subject 2) - Nth

Philippine Electrical Code (Subject 2) - Nth

University

50 Qs

EST 33

EST 33

University

50 Qs

PART 8: MCQ from Number 351 – 400

PART 8: MCQ from Number 351 – 400

University

50 Qs

Journeyman 11 - Nth

Journeyman 11 - Nth

University

50 Qs

Tennez

Tennez

12th Grade - University

50 Qs

Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

Assessment

Quiz

Other

University

Medium

Created by

Norlan Hiponia

Used 32+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. The overhead conductors, through which electrical service is supplied, between the last power company pole and the building or other support used for the purpose are called:

Service entrance

Service-entrance conductors

Service drop

Service-entrance equipment

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. The conductors and equipment for delivering electric energy from the power company to the wiring system of the premises served is called a:

Service

Service-entrance conductors

Service drop

Service-entrance equipment

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3. The conductors between the point of termination of the overhead service drop or underground service lateral and the main disconnecting device in a building are known as:

Service

Service conductors

Service drop

Service-entrance equipment

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4. The necessary equipment connected to the load end of the service conductors to a building or other structure and intended to constitute the main control and cutoff of the supply is known as:

Service entrance

Service-entrance conductors

Service drop

Service equipment

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

5. The underground conductors through which service is supplied between the power company’s distribution facilities and the first point of their connection to a building or area service facilities located at the building or other support used for the purpose are known as:

Service clearance

Service lateral

Parallel connection

Weatherhead

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

6. In a balanced three-phase, 4-wire system, the current in the neutral conductor:

Is the same as in the other conductors

Is lower than in the other conductors

Is higher than in the other conductors

Will not flow when all loads are exactly balanced

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

7. On a 240-volt, single-phase, 3-wire system, the neutral conductor will:

Never carry current even if the other conductors carry current

Never carry current larger than the difference between the current in the two ungrounded (“hot”) conductors

Carry current equal to the current between phases

Carry current equal to one-half the current between phases