PEC BOARD 1

PEC BOARD 1

Assessment

Quiz

Other

University

Easy

Created by

Jonna Rico

Used 7+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fluorescent light fixtures supported independently of an outlet box shall meet which of the following requirements:

May be connected by a metal raceway

May use nonmetallic sheathed romex cable

May be connected by a nonmetallic raceway

All of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Service entrance equipment includes which of the following: I. Panelboards II. Meter enclosures III. Service disconnecting means

I only

II & III only

I & III only

II only

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medium voltage cable insulation is rated for which of the following: a.

600 volts and higher

600 volts and lower

2001 volts and higher

None of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Single phase loads connected to the load side of a phase converter shall not be connected in which of the following manners:

To the manufactured phase

To the grounded phase

To the neutral

To the high leg

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a 480 volt motor has a full-load current of 34 amperes, then the standard disconnecting means must be which of the following:

66 amps

50 amps

39.1 amps

40 amps

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Provided that the calculation for the neutral for the feeder and service is 14550 VA, then the calculated load for neutral for this same 150 square meter singlefamily, one-bath dwelling would be which of the following:

37.5 amps

40.4 amps

60.6 amps

77.5 amps

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum number of branch circuits required for 12 kW range in this same 145 square meter single-family, one-bath dwelling would be which of the following:

Two 2-wire 20 amp circuits

Three 15 amp 2-wire circuits

One 2-wire 20 amp circuit

Two 2-wire 15 amp circuits