Random Fuel Gas

Random Fuel Gas

Professional Development

40 Qs

quiz-placeholder

Similar activities

Performance Christmas Quiz

Performance Christmas Quiz

Professional Development

42 Qs

TARIFF LAW DAY 1

TARIFF LAW DAY 1

Professional Development

40 Qs

Long Quiz

Long Quiz

KG - Professional Development

40 Qs

Central heating trail 4

Central heating trail 4

Professional Development

42 Qs

91E Annual Impact Report

91E Annual Impact Report

Professional Development

39 Qs

Random Plumbing 02

Random Plumbing 02

Professional Development

40 Qs

Cryo Pumps

Cryo Pumps

Professional Development

38 Qs

Type 1 Quiz August 29 - September 4

Type 1 Quiz August 29 - September 4

Professional Development

45 Qs

Random Fuel Gas

Random Fuel Gas

Assessment

Quiz

Other

Professional Development

Easy

Created by

Johnny Thulin

Used 5+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         06.Appliance connections to a chimney or vent equipped with a power exhauster shall be made on the ______________ side of the exhauster.
1.  a.outlet
2.  b.inlet
3.  c.positive
4.  d.discharge
Reference Section(s): 501.10

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         03.Unless incorporated as part of the appliance, a sediment trap shall be installed ___________.
1.  a.downstream of the appliance shutoff valve
2.  b.remote from the appliance location
3.  c.upstream of the appliance shutoff valve
4.  d.upstream of the manifold
Reference Section(s): 408.4

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

25.Within dwelling units, unobstructed _____________ are permitted to convey combustion air.
97. a.shafts
98. b.stud and joist spaces
99. c.chases enclosing chimneys
100.           d.chimneys
Reference Section(s): 304.11, Item 1 Exception

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         09.Field drilled and tapped pipe fittings are permitted under limited conditions when the work is performed by ___________________.
1. a.a licensed pipefitter
2. b.the contractor holding the permit
3. c.an approved third-party agency
4. d.the gas supplier
Reference Section(s): 403.10.5, Item 9.2

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·    02.Appliances having an ignition sources shall be elevated such that the ignition source is not less than ________________ inches above the floor in a private garage.
1.      a.12
2.      b.18
3.      c.6
4.      d.30
Reference Section(s): 305.3

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

9.    09.Hangers for a suspended unit heater must be _________.
1. a.designed by a registered design professional
2. b.steel angle iron
3. c.provided by the appliance manufacturer
4. d.noncombustible
Reference Section(s): 620.2

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

10. 10.Suspended type unit heaters shall be installed with clearances to combustible materials of not less than _______________ inches at the sides of the unit.
1. a.6
2. b.12
3. c.18
4. d.24
Reference Section(s): 620.4

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?