
NPCP SPECIAL
Authored by dream mayang
Professional Development
2nd Grade
Used 9+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
33 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
a Registered and Licen§e(i Master Plumber. without limitations. pursuant to Republi~ Act 1378, as amended. and shall be submitted in _____ of the aforementioned requirements with each application for a permit.
six (6) sets
four (4) sets
2.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
All Administrative Plumbing Personnel, Plumming Inspector shall be a Registered and Licensed Master Plumber in accordance with the provision of
_______, otherwise, known as "Plumbing Law··.
Republic Act 1378
Republic Act 1978
3.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Exception:
Where one building stand in the rear of another building on an interior lot, and no private sewer line is available nor can be constructed to the rear building through an adjoining court, yard or driveway, the building drain from the front building may be extended to the rear building if the existing size is adequate for both buildings and gravity flow is____
possible
impossible
4.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
• Lead and copper sub-pans or linings shall be installed from all conducting substances other than their connecting drain by 6.8 kg asphalt felt or its equivalent and no lead pan or liner shall be constructed of material weighing less than 19.6 kglm 2 . Thickness of copper pans or liners shall be at least ______ thick. Joint in lead pans or liners shall he burned. Joints in copper pans or liners shall be soldered or brazed.
Gauge No. 24 B & S (0.5 mm)
Gauge No. 22 B & S (0.4 mm)
5.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Exception:
Where a grounding system acceptable to the Administrative Authority is installed, inspected, and approved. metallic pipe may be replaced with ____
non-metallic pipe.
Copper pipe.
6.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Note:
For the purpose of this section, "within the building" shall mean ____
within the fixed limits of the building foundation.
within the perimeter center of the building foundation.
7.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
No building water service pipe shall be less than ____ in diameter.
19 mm
12 mm
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?