OPENBOOK EXAM #5

OPENBOOK EXAM #5

University

46 Qs

quiz-placeholder

Similar activities

Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

University

50 Qs

Administrative Order 59 s. 2001 & Annex A

Administrative Order 59 s. 2001 & Annex A

University

42 Qs

OPENBOOK EXAM #6

OPENBOOK EXAM #6

University

50 Qs

GEAS 58

GEAS 58

University

50 Qs

OPENBOOK EXAM #12

OPENBOOK EXAM #12

University

49 Qs

GEAS 29

GEAS 29

University

50 Qs

BL M-02 FIRE CODE FLASHCARDS 01

BL M-02 FIRE CODE FLASHCARDS 01

University - Professional Development

50 Qs

Journeyman 3

Journeyman 3

University

50 Qs

OPENBOOK EXAM #5

OPENBOOK EXAM #5

Assessment

Quiz

Other

University

Easy

Created by

Road RME

Used 26+ times

FREE Resource

46 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Ground-fault protection that functions to open the service disconnecting means ___ protects(s) service conductors or the disconnecting means.

Will

Will not

Adequately

Totally

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The code requires that being panels be separated from outlet boxes that are to be used for mounting fixtures not less than ___ inches.

12

8

6

10

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where outdoor lamp-holders have terminals that puncture the insulation and contact the conductors, they shall be attached only to ___.

Conductors with rubber insulation

Solid conductors

Conductors of the stranded type

A #12 conductor

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Lamp tie wires, mounting screws, and decorative bands on glass lamps space not less than ___ inches from lamp terminals shall be required to be grounded.

1.25

1.5

2

4

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where conduit is threaded in the field, a standard conduit cutting due with a ___ inch taper per foot shall be used.

0.5

0.75

1

1.25

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a straight run of rigid nonmetallic conduit between securely mounted boxes, expansion joints are required where the computed length change due to thermal expansion or contraction is at least ___inch or more.

1/8

1/4

3/8

1/2

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Equipment grounding conductors, when installed, ___ be included when calculating conduit fill.

Should

Shall

Should not   

Shall never

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?