1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
01. When is a common building sewer connecting more than one building to the public sewer allowed?
when the building tenants agree to the shared use of the sewer
when the city sewer system does not extend to the property line
when the common sewer is controlled by a property owners association
when all buildings using the common sewer are located on the same property
Sec. 701.3
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
02. Where the wastewater temperature will exceed __________ °F, the drainage piping material must be rated for the highest temperature of the wastewater.
110.0
120.0
140.0
160.0
Sec. 702.5
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
03. A solvent-cement joint between ABS and PVC plastic piping is __________.
prohibited
permitted in above ground locations only
permitted with yellow primer complying with ASTM D3138
permitted only where the building drain connects to the building sewer
Sec. 705.16.4
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
04. All of the following materials are approved for both above ground and below ground installations of the building drainage system except __________.
polyolefin
polyethylene
polyvinyl chloride
stainless steel
Tables 702.1 and 702.2
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
05. A chemical waste piping system requires __________.
dilution of the chemicals involved
resistance to the undiluted chemicals involved
complete separation from the sanitary drainage system
schedule 80 weight pipe or equivalent
Sec. 702.6
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
06. Mechanical and ________ joints are approved for polyethylene plastic pipe installed underground.
threaded
caulked
solvent-cemented
heat-fusion
Sec. 705.12.1
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
07. The make-up of a solvent cement joint in 6-inch PVC DWV piping requires application of __________.
purple primer
combination primer/solvent cement conforming to ASTM F493
purple primer or solvent cement that is yellow in color
purple primer or solvent cement that is purple in color
Sec. 705.10.2