Medical Gas Systems 2021 51-75

Medical Gas Systems 2021 51-75

Professional Development

25 Qs

quiz-placeholder

Similar activities

All about Kokoy

All about Kokoy

Professional Development

20 Qs

The Wingfeather Saga

The Wingfeather Saga

5th Grade - Professional Development

20 Qs

Chery Sales Process (CSP)

Chery Sales Process (CSP)

Professional Development

20 Qs

Conceptos Generales del Aparato Locomotor

Conceptos Generales del Aparato Locomotor

Professional Development

20 Qs

Certificación Coordinadores

Certificación Coordinadores

Professional Development

20 Qs

Module 20: Système SRS

Module 20: Système SRS

Professional Development

20 Qs

English Fun Quiz

English Fun Quiz

Professional Development

20 Qs

La protecció de dades als centres educatius

La protecció de dades als centres educatius

Professional Development

20 Qs

Medical Gas Systems 2021 51-75

Medical Gas Systems 2021 51-75

Assessment

Quiz

Other

Professional Development

Easy

Created by

Johnny Thulin

Used 6+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Liquid ring compressors, service water and seal water shall be treated to control_________.
A. waterborne pathogens
B. chlorine
C. hyper chlorination
D. all of the above

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Liquid ring compressor system shall have a reserve medical air standby header (1HR) or a____________ as backup.
A. compressor
B. condensate trap
C. bulk system
D. manifold

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The medical air intake shall be located a minimum of _____ from all vehicular exhausts and noxious fumes.
A. 10 ft
B. 15 ft
C. 20 ft
D. 25 ft

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The medical air intake shall be located a minimum of _____ from all doors, windows or other openings in the building.
A. 10 ft
B. 15 ft
C. 20 ft
D. 25 ft

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

In a facility where medical gas or vacuum systems are present and the failure of such equipment or system is likely to cause imminent major injury or death to patients or caregivers, the system shall be designed to meet which Category of requirements?
A. 1
B. 2
C. 3
D. 4

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Category 1 medical-surgical vacuum sources shall, at a minimum, consist of ____________ or more vacuum pumps.
A. two
B. three
C. four
D. one

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Who shall be responsible for developing an emergency plan in the event of medical air loss at a Category 2 facility?
A. Head of maintenance
B. Chief engineer
C. Facility staff
D. Authority having jurisdiction

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?