Waters HPLC Troubleshooting and Quality Parts Seminar

Waters HPLC Troubleshooting and Quality Parts Seminar

1st - 10th Grade

10 Qs

quiz-placeholder

Similar activities

WATER PURIFICATION

WATER PURIFICATION

1st - 5th Grade

15 Qs

Laboratory Equipment

Laboratory Equipment

7th Grade

10 Qs

Bunsen Burner Quiz

Bunsen Burner Quiz

7th Grade

8 Qs

C14.2 - Potable Water

C14.2 - Potable Water

10th - 11th Grade

15 Qs

Bunsen Burner

Bunsen Burner

8th - 10th Grade

10 Qs

Introduction to Chemistry

Introduction to Chemistry

6th - 7th Grade

15 Qs

Chemistry Equipment

Chemistry Equipment

9th - 12th Grade

15 Qs

Circulatory System Review

Circulatory System Review

6th - 9th Grade

11 Qs

Waters HPLC Troubleshooting and Quality Parts Seminar

Waters HPLC Troubleshooting and Quality Parts Seminar

Assessment

Quiz

Chemistry

1st - 10th Grade

Hard

Created by

Wishnu Hadi

Used 9+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Which of the following are the benefits of Waters Quality Parts?

Waters Quality Parts are tested on Waters system – designed specifically for LC optimal performance

Critical clean process during manufacturing to ensure parts are handled properly – greatly reduces chances of contamination

Peace of mind that the valuable LC investment is protected – system warranty is not invalidated by installing third party parts

All of the above

2.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Which statement is correct?

Waters recommends a Performance Maintenance once every two years

All the critical wear-and-tear components are replaced during the Performance Maintenance regardless of the parts’ conditions

User self-performed maintenance is sufficient to ensure system performance

Quality of the mobile phase will not affect the quality of chromatogram

3.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Which is not correct about the troubleshooting workflow?

Having a system benchmark helps me to have a good chromatogram to refer to when there is a suspected LC problem

I am encouraged to use my own sample to setup as system benchmark

Failure fingerprint should have information on how the chromatogram fails and what causes it to fail

Comparing between failure fingerprint helps me to remove any inconsistent failure causes

4.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

What is/are the cause(s) of peak shape problem?

Poor fitting

Column void

Plugged column

Silanol activity from column

All of the Above

5.

MULTIPLE SELECT QUESTION

20 sec • 1 pt

QCRM from Waters can be used to? (Choose all the answers that applies)

Benchmark system performance

Perform routine PQ checks

Diagnose/troubleshoot system issues

Tell which parts to change of the system

6.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Under the current USP 621 guideline, which is the chromatographic parameter that can be adjusted without revalidation?

Gradient method

Detector wavelength

Different L listing column

Column length and particle size for isocratic method

7.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Part-part manakah yang kemungkinan besar bermasalah Jika RSD RT tidak masuk (>2%) Pada system HPLC anda?

Solvent Filter, Inlet Filter, Checkvalve dan Seal-seal Plunger

Solvent filter, Needle, needle Seal dan sample Syringe

Inlet Filter, Check Valve, Injector valve dan flowcell detector

Needle Seal, needle, Sample Syringe dan Injector valve

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?