A building permit issued under the provisions of the National Building Code shall expire and become null and void if
Building System Design

Quiz
•
Design
•
University
•
Medium
metzilou tigbabao
Used 46+ times
FREE Resource
10 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
45 sec • 1 pt
Building or work not commenced within a period of 3 months after issuance of building permit
Building or work is suspended or abandoned at any time after it has been commenced for a period of 1 year
Building or work not commenced within a period of 120 days after issuance of building permit
Building or work is suspended or abandoned at any time after it has been commencing for a period of 120 days
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following minor constructions is NOT exempted from building permits?
Garden masonry walls other than party walls not exceeding 1.20 meters in height, footpaths, residential garden walks and/or driveways
Addition of open terraces or patios resting directly on ground, not exceeding 20 sq. m. in total floor area, exclusively for the private use of the owner
Garden pools for the habitation of water plants and/or aquarium fish not exceeding 200 mm in depth and exclusively for private use
Installation of window grilles
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
6. The number of allowable storeys/floors above established grade for a residential 1 (R-1) type of building is?
3 storeys
4 storeys
5 storeys
6 storeys
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The following are the minimum requirements for Group A dwellings, except
Every dwelling shall be provided with at least one sanitary toilet and adequate washing and drainage facilities
Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least 250 millimeters thick and 600 millimeters below the surface of the ground
Every dwelling shall be so constructed and arranged as to provide adequate light and ventilation
There shall be at least two entrances and another one for exit
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the minimum width of corridor or exit balcony serving as a required exit for an occupant load of more than ten (10)?
1.20 meters
1.10meters
1.00meters
1.25meters
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Juncture of the roof and vertical surfaces, must be provided with
Painting
Ridge roll
Downspout
Flashing
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Who shall be the responsible for carrying out the provision of the Building Code as well as the enforcement of orders?
Building Officials
Authority
Office of the City Engineer
DOH
Create a free account and access millions of resources
Similar Resources on Quizizz
10 questions
AIESEC QUIZ #1

Quiz
•
University
10 questions
System Development Life Cycle (SDLC)

Quiz
•
10th Grade - Professi...
7 questions
IAA641 Urban Revitalization

Quiz
•
University
11 questions
Architectural Layout and Design

Quiz
•
University
15 questions
Building Laws Quiz 2- PD 1096

Quiz
•
KG - Professional Dev...
15 questions
Building Laws Quiz 1- PD 1096

Quiz
•
KG - Professional Dev...
13 questions
No IQ quiz

Quiz
•
KG - University
9 questions
Engineering Analysis

Quiz
•
University
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
20 questions
Math Review - Grade 6

Quiz
•
6th Grade
20 questions
math review

Quiz
•
4th Grade
5 questions
capitalization in sentences

Quiz
•
5th - 8th Grade
10 questions
Juneteenth History and Significance

Interactive video
•
5th - 8th Grade
15 questions
Adding and Subtracting Fractions

Quiz
•
5th Grade
10 questions
R2H Day One Internship Expectation Review Guidelines

Quiz
•
Professional Development
12 questions
Dividing Fractions

Quiz
•
6th Grade