EE 8702_PSOC_UNIT 2_QUIZ_PART 2

EE 8702_PSOC_UNIT 2_QUIZ_PART 2

University

30 Qs

quiz-placeholder

Similar activities

Tears of Themis Anniversary Event Quiz

Tears of Themis Anniversary Event Quiz

University - Professional Development

30 Qs

Welding Electricity

Welding Electricity

University

27 Qs

UNIT I B Compiler Construction Quiz

UNIT I B Compiler Construction Quiz

University

25 Qs

Rolls-Royce 250-C18 Series Overhaul Manual - General Description

Rolls-Royce 250-C18 Series Overhaul Manual - General Description

12th Grade - University

30 Qs

Quiz One Piece Ronde 1

Quiz One Piece Ronde 1

University

30 Qs

Eurodance 90s https://soundcloud.com/luis-pel-ez-palomino/sesion90djluichi2018

Eurodance 90s https://soundcloud.com/luis-pel-ez-palomino/sesion90djluichi2018

University

32 Qs

Cardiac Assessment

Cardiac Assessment

University

34 Qs

Science-Q2-S4-G10

Science-Q2-S4-G10

University

25 Qs

EE 8702_PSOC_UNIT 2_QUIZ_PART 2

EE 8702_PSOC_UNIT 2_QUIZ_PART 2

Assessment

Quiz

Other

University

Medium

Created by

Elavarasu Ramalingam

Used 3+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

In which of the following frequency control method tie lines may be overloaded?

Flat frequency control

Flat tie line control

Parallel frequency

All of the above

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The equation of area control error(ACE) is

 ACE=ΔPtie+bΔfACE=ΔPtie+bΔf  

 ACE=ΔPtiebΔfACE=ΔPtie−bΔf  

 ACE=ΔPtie+1bΔfACE=ΔPtie+1bΔf  

 ACE=ΔPtie1 bΔfACE=ΔPtie−1\ bΔf  

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Power system network has a total power of 5000 MW at 50 Hz supplying to the different consumers. Frequency is varying at 1.5% per change of 2% load. Assume R =0.004 Hz/MW. Find the steady state frequency deviation if a sudden loss of 200 MW occur due to tripping of one of the transmission line?

50 Hz

0.52 Hz

0.48 Hz

-0.52 Hz

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Load frequency and economic dispatch controller are working

Independently

Together with

Sequential

None of above

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Economical dispatch controller has

Fast response

Slow response

Very Fast response

None of above

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

GRCs for which of the power plant is ignored

Hydro

Thermal

Nuclear

All of above

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The effect of speed governor dead band is that

Governor becomes dead

Increase or decrease in the speed occurs before position of control valve changes

Speed becomes constant

None of above