Homewok 4 - Electrical Code Quiz

Homewok 4 - Electrical Code Quiz

Professional Development

33 Qs

quiz-placeholder

Similar activities

POST-TEST

POST-TEST

Professional Development

30 Qs

MEDIWINGS MALAPPURAM

MEDIWINGS MALAPPURAM

Professional Development

30 Qs

IMC Random 01

IMC Random 01

Professional Development

29 Qs

Bed Makings Quiz

Bed Makings Quiz

12th Grade - Professional Development

35 Qs

MGNF 25

MGNF 25

Professional Development

35 Qs

Homework 2 - Electrical Code and Standards Quiz

Homework 2 - Electrical Code and Standards Quiz

Professional Development

37 Qs

INTERNATIONAL FUEL GAS CODE (part 5)

INTERNATIONAL FUEL GAS CODE (part 5)

Professional Development

32 Qs

RME_Chapter 4

RME_Chapter 4

Professional Development

30 Qs

Homewok 4 - Electrical Code Quiz

Homewok 4 - Electrical Code Quiz

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

sofìa hernàndez

FREE Resource

33 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A neutral conductor sized smaller than #6 AWG shall be permitted to have white or gray phase tape at each end of the pull.

True

False

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Outlet receptacles shall be mounted not less than ____ inches above the deck surfaces at a pier and not below the electrical datum plane on a fixed pier at a marina or boat yard.

6 inches

12 inches

18 inches

24 inches

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Type NM and NMC cables are run for temporary branch circuits, but where this type of wiring is run in a structure there shall be a height limitation.

True

False

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Underfloor raceways are run with removable covers. There will be splices made in the raceways. The fill shall not fill more than ____ percent of the raceway. Code

20%

60%

40%

75%

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Messenger-supported wiring shall not be used in a hoist way. Code

True

False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Article 404 covers which of the following

Fixture wires

Switches

Appliances

Receptacles, cord connectors, and attachments plugs (caps)

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Flexible cords can be run through a hole in the wall of a structure as long as it support.

True

False