Electrical Grid Situational-Based MCQs- Advanced to Expert

Electrical Grid Situational-Based MCQs- Advanced to Expert

University

40 Qs

quiz-placeholder

Similar activities

revision class

revision class

University

35 Qs

PCB Design Situational-Based MCQs - Basic to Intermediate

PCB Design Situational-Based MCQs - Basic to Intermediate

University

40 Qs

Operating System Concepts Quiz

Operating System Concepts Quiz

University

40 Qs

Power Electronic Drives Quiz - Basic to Intermediate

Power Electronic Drives Quiz - Basic to Intermediate

University

40 Qs

Electronics Quiz

Electronics Quiz

University

35 Qs

 Hardware Quiz - Basic 01 to Basic 02

Hardware Quiz - Basic 01 to Basic 02

University

40 Qs

Learning Module 4  Electric Circuits

Learning Module 4 Electric Circuits

University

41 Qs

Computer Network Quiz

Computer Network Quiz

University

41 Qs

Electrical Grid Situational-Based MCQs- Advanced to Expert

Electrical Grid Situational-Based MCQs- Advanced to Expert

Assessment

Quiz

Engineering

University

Easy

Created by

Nestor Philips

Used 1+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A sudden disconnection of a large generator from the grid results in:

Frequency increase

Frequency drop and underfrequency protection activation

Voltage overshoot

Synchronization

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In an interconnected grid, a tie-line helps:

Store power

Transfer power between regions and maintain frequency balance

Lower frequency

Protect SCADA

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In case of fault current exceeding the rating of a circuit breaker, what system is added?

Relay

Current transformer

Backup breaker or series reactor

Fuse

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the key parameter monitored by an Automatic Generation Control (AGC)?

Power factor

Frequency deviation and tie-line power

Line voltage

Breaker status

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In real-time grid operations, Area Control Error (ACE) refers to:

Energy difference

Difference in scheduled and actual power flow and frequency

Power loss

Voltage error

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A wind turbine generator connected to the grid must synchronize:

Only voltage

Voltage, frequency, and phase angle

Just current

Temperature

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A large-scale solar PV plant output is fluctuating due to cloud cover. How does the grid handle this?

Disconnect PV

Use spinning reserves or battery storage

Increase fault level

Bypass transformer

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?