Type 3 Quiz

Type 3 Quiz

Professional Development

20 Qs

quiz-placeholder

Similar activities

GSC spag

GSC spag

Professional Development

25 Qs

Computational Thinking

Computational Thinking

Professional Development

21 Qs

#1 EPA 608 Type III

#1 EPA 608 Type III

11th Grade - Professional Development

25 Qs

Core quiz 1 August 15 - August 18

Core quiz 1 August 15 - August 18

Professional Development

20 Qs

WCS 1107-3 - Knowledge Assessment

WCS 1107-3 - Knowledge Assessment

Professional Development

20 Qs

1.5 GSC reviewer

1.5 GSC reviewer

Professional Development

15 Qs

Ora07-003

Ora07-003

Professional Development

15 Qs

SCOOPS TEST!

SCOOPS TEST!

Professional Development

21 Qs

Type 3 Quiz

Type 3 Quiz

Assessment

Quiz

Other

Professional Development

Easy

Created by

Quizizz Content

Used 2+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

The purpose of a hydrostatic tube test is to:

determine if a tube has refrigerant in it

determine if a tube is leaking

determine if the pressure inside of the tube is less than required

none of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A chiller containing 150 pounds of HCFC refrigerant is leaking above the leak rate threshold.  The repair must be completed within ___days unless granted additional time.

repair within 60 days

repair within 35 days

repair within 30 days

not applicable, repair whenever possible

3.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

In order to determine a chillers normal charge for leak rate calculations the best method would be to:

estimate 20lb per ton

estimate 36 lb.per ton

use the charge stated on the equipment nameplate

base charge on manifold pressure readings

4.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

Under Standard 34 R-123 falls under group _________.

Select one:

A1

A2

B1

B2

5.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A technician servicing low- pressure appliances must be certified under

Type III cert. Of section 608

Type II cert. Of section 608

Type I Of section 608

All of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

When recharging a low-pressure system, you should allow enough ____________ to enter the system until the refrigerant saturation temperature increases to _______degrees before introducing liquid refrigerant.

vapor / 32

vapor / 36

liquid / 32

liquid / 36

7.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

During a chiller refrigerant recovery process, you should:

circulate water through the chiller to prevent water from freezing

circulate oil through the chiller to prevent water from freezing

circulate glycol to prevent the chiller water from freezing

either a or b