Sample Questions - Inspection and Test - Paper 2

Sample Questions - Inspection and Test - Paper 2

2nd Grade

29 Qs

quiz-placeholder

Similar activities

Word Study Review Prefixes and Suffixes

Word Study Review Prefixes and Suffixes

2nd - 6th Grade

30 Qs

POSSESIVE ADJECTIVES

POSSESIVE ADJECTIVES

1st - 5th Grade

25 Qs

Acronym: Quiz

Acronym: Quiz

KG - University

26 Qs

Γ-Δ (1)

Γ-Δ (1)

2nd Grade

30 Qs

Cambium Practice*

Cambium Practice*

1st - 5th Grade

27 Qs

UTS SISTEM PAKAR CAW

UTS SISTEM PAKAR CAW

1st Grade - University

25 Qs

Entrep Quiz 2

Entrep Quiz 2

1st - 12th Grade

25 Qs

Nature of Science

Nature of Science

2nd Grade - Professional Development

31 Qs

Sample Questions - Inspection and Test - Paper 2

Sample Questions - Inspection and Test - Paper 2

Assessment

Quiz

Education

2nd Grade

Hard

Created by

James Jones

FREE Resource

29 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On completion of a new installation, the interval before the first periodic inspection would be decided by the:

installer

installation designer

client

inspection and testing engineer

2.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Any addition to an existing installation should:

have a similar wiring system to that used in the existing installation.

be inspected and tested separate from the existing installation.

not impair the safety of the existing installation.

have its own energy meter separate from that of the existing installation.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following duties is ‘not’ the responsibility of the inspector?

to carry out maintenance and repairs on the installation.

to compare the test results with the design criteria.

to advise on remedial works.

to recommend the immediate isolation of defective parts.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4 - Inspection of a fully enclosed domestic consumer unit would not need verification for:

identification of conductors

rating and type of protective devices

insulation resistance between live conductors and earth

correct connection of single-pole devices

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When inspecting for adequate ‘basic protection’ (protection against electric shock or direct contact) which of the following does not require inspection. Presence and condition of:

insulation

enclosures

barriers

cpc’s

6.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

The measured value of loop impedance for a circuit is 2.4Ω. If the temperature at the time of the test was 20°C and the cable is 70°C (factor 1.2) what is the corrected value. Ze = 0.4Ω:

2.88 Ω

2.8 Ω

2.4 Ω

2.0 Ω

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Put the following tests in the correct sequence: 1- Continuity of CPC 2- polarity 3- ring circuit continuity 4- prospective fault current

1.3.2.4

2.4.1.3

4.1.3.2

4.1.2.3