1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How many pieces of ½” drywall (4’ x 8’) are needed to cover the ceiling of a room that measures 32 feet wide and 48 feet long?
24
32
48
1536
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A round concrete column (cylinder) is 15 feet 6 inches in height, the approximate diameter of the column is 21.9 inches, how many yards of concrete are needed to complete this pour?
1.5 yards
1.8 yards
10.95 yards
40.5 yards
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The cost of electricity is 12.75 cents per kilowatt hour (kwh) for the first 1000 hours and 13.9 cents for each kwh greater than 1000 hours. If a pump uses 6.75 kilowatts per hour and it operates 22 days each month for 12 hours each day, what is the approximate monthly kwh charge to operate the pump?
$ 196.30
$ 236.20
$ 274.10
$ 314.00
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A hydraulic cylinder that operates the arm of a skid steer loader has a bore diameter of 3 inches and a stroke of 36 inches. The tractor’s hydraulic system produces a maximum pressure of 2,900 pounds per square inch. Approximately, what is the maximum force the cylinder can exert on the lift arm?
11,099 pounds
14,811 pounds
17,644 pounds
20,488 pounds
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
An 18-wheel tractor trailer is used for hauling hogs to market and cannot legally exceed a total weight of 80,000 lbs. The empty tractor trailer weighs 33,000 lbs. What is the maximum number of 280-pound hogs that can be hauled to market with this tractor trailer?
117
118
167
168
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A water pump has a 3.5-inch diameter pulley that must turn at 1000 revolutions per minute (rpm). The shaft of an electric motor rotates at 1725 rpm and powers the belt that turns the pump's pulley. What is the approximate diameter of the pulley needed on the motor shaft to turn the pump at 1000 rpm?
1.0 inches
1.3 inches
1.7 inches
2.0 inches
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Three incandescent light bulbs (100 Watts, 200 Watts, 300 Watts) are operating properly in a 120-volt electrical circuit. If each bulb operates at 120 volts, which of the following statements is correct in regard to the operation of the bulbs?
All three bulbs operate at the same amperage.
All three bulbs have the same electrical resistance.
The 100-watt light bulb has less electrical resistance (ohms) than the 200- or 300-watt light bulbs.
The 100-watt light bulb has more electrical resistance (ohms) than the 200- or 300-watt light bulbs.
Create a free account and access millions of resources
Similar Resources on Wayground
16 questions
Factor Label / Dimensional Analysis

Quiz
•
9th Grade
15 questions
Dimensional Analysis and Metric Quiz

Quiz
•
9th - 10th Grade
15 questions
Gradient Earth Science

Quiz
•
8th - 11th Grade
20 questions
Science Tools and Safety

Quiz
•
1st - 10th Grade
15 questions
Onshape Unit

Quiz
•
9th Grade - University
15 questions
US Customary Measurement

Quiz
•
7th Grade - University
15 questions
Maps Graphs Charts UIL

Quiz
•
8th Grade - University
15 questions
Topographic maps - Gradient & Slope

Quiz
•
8th - 11th Grade
Popular Resources on Wayground
11 questions
Hallway & Bathroom Expectations

Quiz
•
6th - 8th Grade
20 questions
PBIS-HGMS

Quiz
•
6th - 8th Grade
10 questions
"LAST STOP ON MARKET STREET" Vocabulary Quiz

Quiz
•
3rd Grade
19 questions
Fractions to Decimals and Decimals to Fractions

Quiz
•
6th Grade
16 questions
Logic and Venn Diagrams

Quiz
•
12th Grade
15 questions
Compare and Order Decimals

Quiz
•
4th - 5th Grade
20 questions
Simplifying Fractions

Quiz
•
6th Grade
20 questions
Multiplication facts 1-12

Quiz
•
2nd - 3rd Grade