8202 9189 CJ Cold Water Systems Quiz

8202 9189 CJ Cold Water Systems Quiz

Professional Development

20 Qs

quiz-placeholder

Similar activities

H2S awareness

H2S awareness

Professional Development

15 Qs

Fundamental of Common Rail Diesel Fuel System

Fundamental of Common Rail Diesel Fuel System

University - Professional Development

15 Qs

engine diesel komponen

engine diesel komponen

Professional Development

25 Qs

Interceptor 650 Quiz

Interceptor 650 Quiz

Professional Development

15 Qs

Team Expert PCS

Team Expert PCS

Professional Development

15 Qs

Domestic Heating Compliance Quiz

Domestic Heating Compliance Quiz

Professional Development

20 Qs

Maritime Glossary 6 - OHM

Maritime Glossary 6 - OHM

Professional Development

20 Qs

AUC MTM Week 2

AUC MTM Week 2

Professional Development

20 Qs

8202 9189 CJ Cold Water Systems Quiz

8202 9189 CJ Cold Water Systems Quiz

Assessment

Quiz

Specialty

Professional Development

Hard

Created by

Chris Jackson

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can the cold water supply pressure to a property be identified?

By contacting the local council or using a weir gauge at the kitchen sink

By contacting the local council or using a pressure gauge at the supply to the FOV

By contacting the water undertaker or using a pressure gauge at the cistern-fed outlets

By contacting the water undertaker or using a pressure gauge at the kitchen sink

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which formula can be used to determine flow rates through a pipe?

Q = Av

Q = A÷v

Q = m/s

Q = V²

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What term is given to the length of pipe when all fittings and components are considered during pipe sizing?

Equivalent length

Actual length

Mean length

Velocity length

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a source of information that should be consulted to assist in pipe sizing for cold water systems?

BS EN 806 -2: 2012

BS EN 806-3: 2012

BS 8558: 2015

BS 4213: 2004

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to guidance, all pipes and joints of a cold water system should be designed for a service life of:

25 years at a temperature of 20°C and a design pressure of 15 bar

50 years at a temperature of 20°C and a design pressure of 10 bar

25 years at a temperature of 25°C and a design pressure of 10 bar

50 years at a temperature of 25°C and a design pressure of 5 bar

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended storage capacity of a CWSC supplying cold and hot water to a house?

100 litres minimum

150 litres minimum

230 litres minimum

350 litres minimum

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended flow velocity of cold water within pipework?

Between 0.25m/s and 1.5m/s

Between 0.5m/s and 2m/s

As close as practically possible to 2.5m/s

As close as practically possible to 3.5m/s

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?