Electricity Unit 14 Review

Electricity Unit 14 Review

Professional Development

21 Qs

quiz-placeholder

Similar activities

Electrical Science Revision 11th December

Electrical Science Revision 11th December

Professional Development

25 Qs

Burger

Burger

Professional Development

20 Qs

SOAL BDE AA

SOAL BDE AA

Professional Development

18 Qs

Pre - Evaluation Electrical Troubleshooting Methodologies

Pre - Evaluation Electrical Troubleshooting Methodologies

Professional Development

20 Qs

Motor Vehicle MV2 152 Mock

Motor Vehicle MV2 152 Mock

Professional Development

24 Qs

ROBONETICSSOLUTIONS

ROBONETICSSOLUTIONS

Professional Development

20 Qs

MAF Sensors (AE06)

MAF Sensors (AE06)

Professional Development

20 Qs

ERM - Written Exam - Star Assistant

ERM - Written Exam - Star Assistant

Professional Development

20 Qs

Electricity Unit 14 Review

Electricity Unit 14 Review

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

Robert Hemmila

Used 3+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

21 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A heating and cooling system will operate properly using jumper wires to manually complete the control circuits at the low-voltage thermostat, but the system will not operate with the jumper wires removed, the _______________ is the likely cause of the malfunction.

Control transformer

Thermostat

Contactor

Control wiring

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A motor with a rating of 15 full load amps is protected by a line voltage overload that keeps opening at a current draw of 14 amps, indicating the overload is ___________.

Good

Shorted

Weak

Too large for the motor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A reading of line voltage across the contacts of a sequencer indicates the contacts are _______________.

Open

Shorted

Closed

None of the choices are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electric heating system controlled by a sequencer is not heating. If the technician reads 240 volts across each contact of the sequencer and zero volts across the sequencer element, which of the following is likely the cause of the malfunction?

The sequencer contacts are stuck open

The thermostat is not sending 24 volts to the sequencer element

The sequencer element is open

The sequencer contacts are stuck closed

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For a technician to determine if a pressure switch is faulty, the technician needs to know __________________.

The function of the pressure switch

The pressure settings of the switch

The pressure in the refrigeration system

All of the choices are correct

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Motors are very important loads in heating, cooling, and refrigeration equipment because they are used to rotate ___________________.

Fans

Compressors

Pumps

All of the choices are correct

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The internal overload used on most modern single-phase hermetic compressors is in the _____________ terminal of the motor.

Common

Run

Start

All of the choices are correct

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?

Discover more resources for Professional Development