Search Header Logo

Refrigeration System Knowledge Assessment

Authored by Lucas Neal

Architecture

10th Grade

Used 5+ times

Refrigeration System Knowledge Assessment
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of a moisture indicating sight glass in a refrigeration system?

To check the refrigerant level

To check the refrigerant for moisture

To measure the pressure of the refrigerant

To regulate the flow of refrigerant

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why should the liquid-line filter drier be replaced anytime a system is opened for service?

It becomes clogged with refrigerant

It loses its ability to filter moisture

It is a regulatory requirement

It is a standard maintenance procedure

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the consequence of closing the discharge service valve on an operating reciprocating compressor?

It will increase the efficiency of the compressor

It can result in compressor damage and severe personal injury

It will decrease the system pressure

It will improve the cooling capacity

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How does a crankcase heater help in a refrigeration system?

By increasing the refrigerant pressure

By reducing the amount of refrigerant in the oil and reducing oil foaming

By cooling the compressor

By increasing the system's cooling capacity

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of using nitrogen when evacuating a system with large amounts of moisture?

To increase the system pressure

To counteract freezing of the moisture

To reduce the refrigerant charge

To improve the efficiency of the vacuum pump

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is it important to maintain system pressure slightly above atmospheric pressure in an idled low-pressure refrigeration system?

To prevent refrigerant loss

To prevent air accumulation

To increase system efficiency

To reduce maintenance costs

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum test pressure when leak testing a low-pressure centrifugal chiller with nitrogen?

5 psig

10 psig

15 psig

20 psig

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?