EPA Section 608 Type I_C

EPA Section 608 Type I_C

University

10 Qs

quiz-placeholder

Similar activities

Technology-based Interactive Teaching Strategy

Technology-based Interactive Teaching Strategy

University

12 Qs

Physiology of vision

Physiology of vision

University

15 Qs

Midterm Examination 1.1 (Software Design)

Midterm Examination 1.1 (Software Design)

University

15 Qs

EPA Section 608 Core C

EPA Section 608 Core C

University

10 Qs

EPA Section 608 Type I_A

EPA Section 608 Type I_A

University

10 Qs

Air Conditioning System Quiz

Air Conditioning System Quiz

University

10 Qs

Prelim Quiz 3

Prelim Quiz 3

University

10 Qs

كوكيز

كوكيز

University

10 Qs

EPA Section 608 Type I_C

EPA Section 608 Type I_C

Assessment

Quiz

Others

University

Medium

Created by

sikrtz yt

Used 8+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When installing any type of access fitting onto a sealed system the fitting should be __________ before proceeding with recovery.

on the evaporator

removed

on the condenser

leak tested

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To ensure that all CFC, HCFC, or HFC refrigerant has been removed from a frost-free refrigerator, the __________ can be energized to increase the refrigerant's temperature and vaporize any liquid.

condenser fan motor

evaporator fan motor

defrost heater

compressor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Because __________ tend to leak over time, they should not remain on the refrigeration systems after completion of the repair.

A. schrader valves

B. solderless type piercing valves

C. service valves

D. all answers are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An appliance with an operating compressor and completely restricted capillary tube or metering device requires __________.

only one access valve on the low side of the system

only one access valve on the high side of the system

two access valves on the system

two access valves on the high side of the system

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A __________ recovery process for small appliances can capture refrigerant in a non-pressurized container.

passive, self-contained

active, system-dependent

passive, system-dependent

active, self-contained

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the pressure in an appliance is at __________ after installing and opening a piercing access valve, the recovery procedure cannot begin.

0 psig

100 psig

10" Hg.

4" Hg.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When using the __________ recovery process and the compressor does not run, both the high and low side of the system must be accessed for refrigerant recovery.

system-dependent (passive)

system-dependent (active)

self-contained (passive)

self-contained (active)