Progress check hot water

Progress check hot water

12th Grade

26 Qs

quiz-placeholder

Similar activities

Plumbing Processes PPT 2 - Power Tools

Plumbing Processes PPT 2 - Power Tools

12th Grade - University

25 Qs

Condenser Unit Quiz

Condenser Unit Quiz

12th Grade

27 Qs

HSSE REVISION MCQ

HSSE REVISION MCQ

12th Grade

30 Qs

Quizizz 4B

Quizizz 4B

12th Grade

25 Qs

knowledge check 3

knowledge check 3

12th Grade

27 Qs

Tools

Tools

9th Grade - University

30 Qs

Understand the requirements of drainage systems

Understand the requirements of drainage systems

12th Grade

31 Qs

PPT 9 - Install and test systems and components

PPT 9 - Install and test systems and components

12th Grade

28 Qs

Progress check hot water

Progress check hot water

Assessment

Quiz

Construction

12th Grade

Easy

Created by

Nigel Pawlett

Used 1+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

26 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum recommended distribution temperature of hot water supplied by a storage cylinder?

48°C

55°C

60°C

65°C

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which Building Regulation relates to the hot water delivery systems in dwellings?

Part F

Part G

Part P

Part L

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is classed as a localised hot water system?

Under-sink single point heater

Thermal store

Combination boiler

Open vented

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The safety devices within an unvented hot water cylinder are designed to prevent the water from exceeding which of the following temperatures?

60°C

65°C

95°C

100°C

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should a secondary return be connected within a hot water storage cylinder?

A quarter of the way down

Halfway down

Two-thirds of the way from the bottom

A quarter of the way up

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Identify the components in the unvented hot water system below.

1: Strainer; 2: Isolation valve; 3: Expansion relief valve; 4: Check valve

1: Isolation valve; 2: Strainer; 3: Check valve; 4: Expansion relief valve

1: Pressure reducing valve; 2: Isolation valve; 3: Check valve; 4: Strainer

1: Isolation valve; 2: Strainer; 3: Pressure reducing valve; 4: Check valve

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What temperature should the temperature relief valve fitted to an unvented hot water storage vessel be set to discharge at?

60°C

72°C

90°C

95°C

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?