UNIT 264: Mock Paper 4

UNIT 264: Mock Paper 4

Professional Development

30 Qs

quiz-placeholder

Similar activities

Aberoth

Aberoth

Professional Development

25 Qs

Abacus level 1

Abacus level 1

Professional Development

25 Qs

Unit 262 – Multiple choice practice exam

Unit 262 – Multiple choice practice exam

Professional Development

27 Qs

panel discussion technical informal

panel discussion technical informal

Professional Development

25 Qs

Abstract Reasoning Pretest

Abstract Reasoning Pretest

Professional Development

25 Qs

Final Exam 2023-24 Review I

Final Exam 2023-24 Review I

Professional Development

25 Qs

LNMIIT Quiz 22nd May

LNMIIT Quiz 22nd May

Professional Development

25 Qs

Simplification Test-1

Simplification Test-1

Professional Development

25 Qs

UNIT 264: Mock Paper 4

UNIT 264: Mock Paper 4

Assessment

Quiz

Mathematics

Professional Development

Hard

Created by

yusuf Abubakar

Used 1+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Full form of PILCSTA on cables

Paper insulated lead covered steel wire armoured

Plastic insulated lead covered steel wire armoured

Paper insulated lead covered steel tape armoured

Paper insulated laminated copper steel tape armoured

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. 3c 300 SAC XLPE 11KV on a cable record means

3 core 300sqmm Copper unsheathed 11KV

3 x 1 core 300sqmm Aluminium lead sheathed 11 KV

3 Core 300sqmm Solid Aluminium Conductor 11KV

3Core 300sqmm Stranded Copper Conductor 11KV

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When is a circuit main earth applied to an overhead line?

After the issue of a safety document

Before the issue of a safety document

Before the line is isolated

After the additional earths have been applied

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Electrolytic action takes place:

Where dissimilar metal conductors are used

A reaction inside an overhead line transformer

The amount of current a conductor can hold

A low resistance joint

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum open ground clearance for an LV overhead line?

6.4m

5.2m

2.8m

4.2m

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why are stockbridge dampers used on the overhead line steel towers?

To reduce damage due to lightening

To increase conductor strength

To increase insulator resistance

To reduce damage due to vibration

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When handling cold pour resins the mandatory PPE would be

Overalls and eye protection

Disposable gloves and breathing apparatus

Breathing apparatus and overall

Eye protection and disposable gloves

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?