Search Header Logo

EPA 608 Exam Study Type II

Authored by Bob TheBuilder

Instructional Technology

11th Grade

Used 64+ times

EPA 608 Exam Study Type II
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is best practice to use dry nitrogen to break the vacuum when dehydrating by the triple evacuation method. However, it;

often contains moisture

requires a minimum of 10 psig

is toxic when released into the environment

requires a pressure regulator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When can appliances containing refrigerants be recovered to atmospheric pressure?

for major repairs such as replacing the compressor , condenser, or evaporator

the repair is followed by an evacuation of the appliance to the environment

leaks in the appliance make recovery to the prescribed level unattainable

the appliance is being disposed of and recycled

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following repairs would always be considered "major" under EPA's regulations

Replacement of an evaporator coil

Replacement of a filter-drier

Replacement of a Schrader valve core

Replacement of a condenser fan motor

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Before making a major repair, technicians must evacuate an appliance or component containing more than 200 pounds of R-410A to which of the following levels?

0 PSIG

25mm Hg absolute

10 inches of Hg vacuum

15 inches of Hg vacuum

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can you speed up the removal of the refrigerant charge from a system?

using a smaller recovery vessel

cooling the recovery cylinder to lower it's pressure

using a two-stage vacuum pump

heating the recovery cylinder to raise it's pressure

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

You are changing out the compressor of a system containing 40 pounds of R-404A. In addition to isolating the compressor, which of the following procedures should you follow?

simply remove the compressor and cap the ends

evacuate the isolated section of the system to atmospheric pressure, then remove the compressor

evacuate the isolated section of the system to 0 PSIG and if system pressure does not rise after a few minutes remove the compressor

evacuate the isolated section of the system to 18" Hg and if system pressure does not rise after a few minutes energize the compressor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How would you remove moisture from refrigerant in a system?

purge the condenser

drain the oil seperator

reduce water flow to the condenser

use a filter-drier

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?