Hot water system | Quiz

Hot water system | Quiz

Professional Development

20 Qs

quiz-placeholder

Similar activities

Phase 2 Exam prep 1

Phase 2 Exam prep 1

Professional Development

20 Qs

S-presso & Baleno

S-presso & Baleno

Professional Development

20 Qs

Mechanic of the month juni 2025

Mechanic of the month juni 2025

Professional Development

20 Qs

HAC101 Week 2 Quiz Heating & Ventilation

HAC101 Week 2 Quiz Heating & Ventilation

Professional Development

20 Qs

Wet System Components

Wet System Components

Professional Development

15 Qs

Transmission I-Shift Series G (Advanced Volvo)

Transmission I-Shift Series G (Advanced Volvo)

Professional Development

25 Qs

Phase 2 Exam prep 2

Phase 2 Exam prep 2

Professional Development

20 Qs

AUT108 Fuel Management Systems

AUT108 Fuel Management Systems

Professional Development

20 Qs

Hot water system | Quiz

Hot water system | Quiz

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

George Harding

Used 15+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum recommended distribution temperature of hot water supplied by a storage cylinder?

48°C

55°C

60°C

65°C

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which Building Regulation relates to the hot water delivery systems in dwellings?

Part F

Part G

Part P

Part L

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is classed as a localised hot water system?

Under-sink single point heater

Thermal store

Combination boiler

Open vented

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Within an open vented hot water system, which of the following are the correct connection methods for the open vent pipe off the draw-off pipe?

Open vent a minimum of 15mm diameter connected within 450mm of the draw-off connection from the cylinder

Open vent a minimum of 15mm diameter connected within at least 450mm of the draw-off point from the cylinder

Open vent a minimum of 22mm diameter connected within 450mm of the draw-off connection from the cylinder

Open vent a minimum of 22mm diameter connected within at least 450mm of the draw-off point from the cylinder

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The safety devices within an unvented hot water cylinder are designed to prevent the water from exceeding which of the following temperatures?

60°C

65°C

95°C

100°C

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should a secondary return be connected within a hot water storage cylinder?

A quarter of the way down

Halfway down

Two-thirds of the way from the bottom

A quarter of the way up

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Identify the components in the unvented hot water system.

1, Strainer

2, Isolation valve

3, Expansion relief valve

4, Check valve

1, Isolation valve

2, Strainer

3, Check valve

4, Expansion relief valve

1, Pressure reducing valve

2, Isolation valve

3, Check valve

4, Strainer

1, Isolation valve

2, Strainer

3, Pressure reducing valve

4, Check valve

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?

Discover more resources for Professional Development