FAB-101 EPA Week 5 Homework (Type III)

FAB-101 EPA Week 5 Homework (Type III)

12th Grade

15 Qs

quiz-placeholder

Similar activities

Quiz Sistem Otomasi II (M6)

Quiz Sistem Otomasi II (M6)

University

10 Qs

TUTORIAL 2 -LUBRICATION

TUTORIAL 2 -LUBRICATION

University

10 Qs

SEPARATION PROCESS PART 1

SEPARATION PROCESS PART 1

University

20 Qs

EMS Sensor

EMS Sensor

University

20 Qs

Exploring Geothermal and Hydrogen Energy

Exploring Geothermal and Hydrogen Energy

University

20 Qs

Flow & Flame Quiz Week II

Flow & Flame Quiz Week II

University

20 Qs

Fundamentals of compressible flow (CO1)

Fundamentals of compressible flow (CO1)

University

15 Qs

CIVILWAR DAY 24 - KWA (ESTIMATION,FM)

CIVILWAR DAY 24 - KWA (ESTIMATION,FM)

1st Grade - University

10 Qs

FAB-101 EPA Week 5 Homework (Type III)

FAB-101 EPA Week 5 Homework (Type III)

Assessment

Quiz

Engineering

12th Grade

Practice Problem

Easy

Created by

Steven Estrada

Used 4+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum test pressure for leak testing a low-pressure centrifugal chiller with nitrogen?

5 psig

10 psig

15 psig

20 psig

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can charged low-pressure refrigeration machines be most effectively leak checked?

By adding refrigerant

By reducing pressure

By adding heat with hot water or heating blankets

By cooling the system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of compressors are particularly susceptible to leaks from the shaft seal?

Open-drive type compressors

Closed-drive type compressors

Rotary compressors

Scroll compressors

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to ASHRAE Guideline 3, when should a system be checked for leaks?

If pressure rises from 1 mm Hg to 2.5 mm Hg

If pressure drops from 2.5 mm Hg to 1 mm Hg

If temperature increases

If refrigerant levels decrease

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What happens once the threshold leak rate has been exceeded on a system using a regulated refrigerant?

The system must be replaced

The system must be repaired

The refrigerant must be removed

The refrigerant must be increased

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As of January 1, 2019, what is the maximum leak rate for comfort cooling?

10% of the charge per year

20% of the charge per year

30% of the charge per year

40% of the charge per year

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How long does an owner have to repair an appliance that has 50 pounds or more of refrigerant and has exceeded the threshold leak rate?

10 days

18 months

30 days

3 years

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?