What is the purpose of pressure regulation in a natural gas distribution network?

Mock ACS Quiz

Quiz
•
Other
•
12th Grade
•
Hard

Gareth Ellison
Used 2+ times
FREE Resource
59 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Close the supply.
Ensure safe delivery.
Prevent gas leaks.
Open the supply.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of a pressure regulator fitted on the inlet to a primary gas meter?
To maintain a defined pressure to a system, by adjusting the flow of gas.
To adjust the pressure so that it meets the needs of the system design.
To maintain and monitor pressure to a system, by cutting off the gas flow in an emergency.
To remove pressure and prevent damage to the system in an emergency.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the most likely cause of pressure loss when carrying out a tightness test?
An overrated gas appliance on the system.
The regulator letting by during the test period.
A gas escape somewhere on the system.
The ECV letting by during the test period.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which statement correctly describes how a dangerous occurrence could happen during the combustion process?
Incomplete combustion due to insufficient oxygen, which results in carbon monoxide.
Incomplete combustion due to excessive oxygen, which results in carbon monoxide.
Incomplete combustion due to insufficient oxygen, which results in carbon dioxide.
Incomplete combustion due to excessive oxygen, which results in carbon dioxide.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How is evidence of incomplete combustion on a gas appliance identified?
A blue flame is present.
The appliance is hot to touch.
Noisy burner when in operation.
Soot deposits around the appliance.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the required activation time for a carbon monoxide alarm, when exposed to a concentration of 100 ppm?
Between 10 minutes and 40 minutes
Within 10 minutes
Between 45 minutes and 60 minutes
After 60 minutes
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A new hair salon has recently opened. A carbon monoxide detector in the salon is being activated intermittently during business hours. A new room-sealed appliance was recently installed on the premises; a gas-safe engineer has confirmed that the appliance is in good working order. What is the cause of this issue?
Heat produced by electrical panel heaters.
Aerosol products used on hair.
Warm air currents from hair dryers.
Bright lighting used during business hours.
Create a free account and access millions of resources
Similar Resources on Quizizz
58 questions
6035ELECTPPT2

Quiz
•
12th Grade
59 questions
Construction Site Safety Basics Unit Review

Quiz
•
9th - 12th Grade
54 questions
Types of Boilers Quiz

Quiz
•
12th Grade
56 questions
6035ELECTPPT1

Quiz
•
12th Grade
56 questions
Heating Systems Quiz

Quiz
•
12th Grade
59 questions
ESS1A Universe

Quiz
•
10th - 12th Grade
58 questions
Immersion Heaters Quiz

Quiz
•
12th Grade
61 questions
Building Regulations Quiz

Quiz
•
12th Grade
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
20 questions
Math Review - Grade 6

Quiz
•
6th Grade
20 questions
math review

Quiz
•
4th Grade
5 questions
capitalization in sentences

Quiz
•
5th - 8th Grade
10 questions
Juneteenth History and Significance

Interactive video
•
5th - 8th Grade
15 questions
Adding and Subtracting Fractions

Quiz
•
5th Grade
10 questions
R2H Day One Internship Expectation Review Guidelines

Quiz
•
Professional Development
12 questions
Dividing Fractions

Quiz
•
6th Grade