Class 2 CC Explosion

Class 2 CC Explosion

University

10 Qs

quiz-placeholder

Similar activities

Kuis Gas dan Termodinamika

Kuis Gas dan Termodinamika

University

10 Qs

Quiz on Thermodynamics of Water

Quiz on Thermodynamics of Water

University

10 Qs

Ing Rocío

Ing Rocío

University

10 Qs

20CE211 - Concrete Technology - Surprise Quiz 02

20CE211 - Concrete Technology - Surprise Quiz 02

University

10 Qs

MEACS Electricals 1

MEACS Electricals 1

University

7 Qs

TUTORIAL 2 -LUBRICATION

TUTORIAL 2 -LUBRICATION

University

10 Qs

Final Examination in MATH 133 - Part 02

Final Examination in MATH 133 - Part 02

University

13 Qs

Quizz de Fundações

Quizz de Fundações

University

11 Qs

Class 2 CC Explosion

Class 2 CC Explosion

Assessment

Quiz

Engineering

University

Practice Problem

Medium

Created by

CE C.S.Prawinraj

Used 4+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What are the components of fire triangle?

Heat

Air

Fuel

All are correct

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

SOLAS regulations to prevent crankcase explosions came into place after a particularly devastative explosion that claimed the lives of 28 people onboard ____

MV Herald Enterprise

MV Reena Dal Pacin

MT Rina Disaster

MV Reina Del Pacifico

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the flash point of main engine crankcase lubricating oil?

-188 deg C

60 deg C

220 K

220 deg C

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

SOLAS regulations to prevent crankcase explosions came into place in ____

1964

1947

1974

1800

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Crankcase relief door also prevents the exit of flame outside of engine by using a ____

non-return valve

flame arrester

return valve

water spray

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Generally, OMD alarm will operate when it reaches a oil mist concentration of ____.

25-50% LEL

2.5-5% HEL

100% LEL

2.5-5% LEL

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

When oil mist alarm is received, it is required to wait for minimum ____ before opening the crankcase doors.

30 hours

30 seconds

30 minutes

All are correct

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?