Heat pump

Heat pump

University

99 Qs

quiz-placeholder

Similar activities

Energy and Power Part 1

Energy and Power Part 1

11th Grade - University

94 Qs

OPAMP Quiz

OPAMP Quiz

University

94 Qs

CMPE 30184 PRE-FINAL EXAMINATION

CMPE 30184 PRE-FINAL EXAMINATION

University

100 Qs

Understanding Memory Management Concepts

Understanding Memory Management Concepts

University

100 Qs

Material Pesawat Terbang dan Manufaktur I

Material Pesawat Terbang dan Manufaktur I

University

100 Qs

Câu hỏi về VLAN và mạng

Câu hỏi về VLAN và mạng

University

98 Qs

Mekanika Kekuatan Material

Mekanika Kekuatan Material

University

100 Qs

Cấu Kiện Điện Tử - Transistor BJT

Cấu Kiện Điện Tử - Transistor BJT

University

101 Qs

Heat pump

Heat pump

Assessment

Quiz

Engineering

University

Easy

Created by

Loudens Loudens

Used 17+ times

FREE Resource

99 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an

Reversing valve

Demand defrost happens only when needed and timed defrost is based on time/temperature.

Slightly above the initial balance point.

Initial balance point

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the;

Initial balance point

Cooling load.

As near to the main return air grill as possible.

Emergency heat mode.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the difference between "demand defrost" and "timed defrost"?

Demand defrost happens only when needed and timed defrost is based on time/temperature.

In a moderate climate zone.

Simply disconnect power to the unit momentarily.

Dividing the Btu's removed by the watts consumed during the cooling season.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the;

Outdoor ambient thermostat

Emergency heat mode.

Emergency heat mode.

Simply disconnect power to the unit momentarily.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At what temperature is an outdoor ambient thermostat normally set?

Slightly above the initial balance point.

Two outdoor coils with each one incorporating a dual stage compressor.

Emergency heat mode.

As near to the main return air grill as possible.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is;

The outdoor fan is inoperative.

The building's heat load.

Cooling load.

Two outdoor coils with each one incorporating a dual stage compressor.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to determine a heat pumps' balance point, you must first calculate;

The building's heat load.

Cooling load.

Two outdoor coils with each one incorporating a dual stage compressor.

As near to the main return air grill as possible.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?