Phase4.mod13.chimney test

Phase4.mod13.chimney test

Professional Development

7 Qs

quiz-placeholder

Similar activities

Hydrocarbons

Hydrocarbons

8th Grade - Professional Development

10 Qs

Bosch Technical Support - basic knowledge check

Bosch Technical Support - basic knowledge check

Professional Development

11 Qs

DUBAI 2020_DAY 2

DUBAI 2020_DAY 2

Professional Development

10 Qs

Action Research

Action Research

University - Professional Development

10 Qs

synthetic fibres and plastics

synthetic fibres and plastics

KG - Professional Development

10 Qs

Fungal Pathogens

Fungal Pathogens

Professional Development

12 Qs

THE LIGHT BULB

THE LIGHT BULB

KG - Professional Development

10 Qs

Sience

Sience

1st Grade - Professional Development

7 Qs

Phase4.mod13.chimney test

Phase4.mod13.chimney test

Assessment

Quiz

Science

Professional Development

Practice Problem

Medium

Created by

Craig Boothright

Used 5+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If there is an extractor fan fitted in an adjacent room to where a spillage test is being performed, the gas operative must:

Turn the fan on and open the adjoining door.

Turn on the fan and close the adjoining door.

Turn the fan off and open the adjoining door.

Turn off the fan and close the adjoining door.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The gas operative need only carry out a spillage test when installing an appliance:

True.

False.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A Flue Flow test must be carried out using a smoke pellet and the appliance.

Turned off.

Turned on low rate.

Turned on full rate.

It may be either on or off.

4.

FILL IN THE BLANK QUESTION

1 min • 1 pt

When carrying out a spillage test the doors, windows and any adjustable vents in the appliance room must be:

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If during the flue flow test the gas operative observes smoke exiting the flue into an upstairs room, the action to be taken must be to:

Treat as Immediately Dangerous.

Treat as At Risk.

Treat as Not to current standards.

Inform Gas Safe Register.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A spillage Test must be carried out using a smoke match or taper with the appliance:

Turned off.

Turned on low rate.

Turned on full rate.

It may be either on or off.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a spillage test is carried out on an open flued boiler , The smoke match holder must be placed near the:

Burner.

Draught diverter.

Combustion air inlet.

Convection air inlet.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?